FireCADCalc

Sludge Age (SRT) and Waste Sludge Flow

Sludge age from aeration tank volume, MLSS and the solids wasted and lost in the effluent, and the waste sludge flow for a target sludge age.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 1500 m3 basinLong sludge age

Results

Solids in the aeration tank4,500.0kg
Present sludge age11.538d
Waste flow for the target41.000m³/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1500 m3 basin. The inputs, in the units selected above:

InputValue
Aeration tank volume1,500.0 m³
MLSS3,000.0 mg/L
Waste sludge flow (from the return line)35.000 m³/d
Return sludge concentration10,000 mg/L
Effluent flow2,000.0 m³/d
Effluent suspended solids20.000 mg/L
Target sludge age10.000 d

Applying the formula below gives:

ResultValue
Solids in the aeration tank4,500.0 kg
Present sludge age11.538 d
Waste flow for the target41.000 m³/d

Open this example in the calculator and change any input.

Formula

\(\theta_c = \frac{V X}{Q_w X_r + Q_e X_e}, \quad Q_{w,t} = \frac{VX/\theta_t - Q_e X_e}{X_r}\)

Variables

Symbol Meaning SI unit
\(V\) Aeration tank volume m³
\(X\) MLSS kg/m³
\(Q_w\) Waste sludge flow (from the return line) m³/s
\(X_r\) Return sludge concentration kg/m³
\(Q_e\) Effluent flow m³/s
\(X_e\) Effluent suspended solids kg/m³
\(\theta_t\) Target sludge age s
\(M\) Solids in the aeration tank kg
\(\theta_c\) Present sludge age s
\(Q_{w,t}\) Waste flow for the target m³/s

Method and standards

Solids balance.

Where it is used

  • ETP operation.
  • Operator examinations.

Common mistakes

  • Ignoring effluent solids.
  • Wasting from the tank at MLSS but using X_r.

Assumptions and limits

  • Steady state.
  • If no solids leave, the sludge age is not defined and is not shown. If the effluent solids alone exceed the loss the target allows, the waste flow is 0 and the page warns that the target cannot be met.

References

  • θ_c = V X/(Q_w X_r + Q_e X_e) (Metcalf & Eddy)

Questions and answers

1500 m³ at 3000 mg/L, wasting 35 m³/d at 10,000 mg/L?

Sludge age about 11.5 days.

For 10 days?

Waste about 41 m³/d.

Why control SRT?

It sets the biology: nitrifiers need longer sludge ages.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.