Sludge Volume Index (SVI) and Settleability

Sludge volume index from the 30-minute settled volume and MLSS, with the settleability band and the return ratio that the settled volume implies.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Borderline goodBulking sludgeDense sludge

Results

Bands are a common rule of thumb; dilute the sample if SV₃₀ exceeds about 250–300 mL/L.

Sludge volume index (mL/g)100.00
Settleability (1 good < 100, 2 fair 100–150, 3 poor > 150)2.0000
Return ratio implied SV/(1000 − SV)42.857%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Borderline good. The inputs, in the units selected above:

InputValue
Settled volume after 30 min (mL/L)300.00 -
Mixed liquor suspended solids3,000.0 mg/L

Applying the formula below gives:

ResultValue
Sludge volume index (mL/g)100.00
Settleability (1 good < 100, 2 fair 100–150, 3 poor > 150)2.0000
Return ratio implied SV/(1000 − SV)42.857 %

Open this example in the calculator and change any input.

Formula

\(SVI = \frac{SV_{30} \times 1000}{MLSS}, \quad R = \frac{SV_{30}}{1000 - SV_{30}}\)

Variables

Symbol Meaning SI unit
\(SV_{30}\) Settled volume after 30 min (mL/L) -
\(MLSS\) Mixed liquor suspended solids kg/m³
\(SVI\) Sludge volume index (mL/g) -
\(\text{band}\) Settleability (1 good < 100, 2 fair 100–150, 3 poor > 150) -
\(R\) Return ratio implied SV/(1000 − SV) -

Method and standards

Definitions.

Where it is used

  • ETP activated sludge control.
  • Operator examinations.

Common mistakes

  • MLSS in g/L with the 1000 factor.
  • Undiluted dense samples.

Assumptions and limits

  • 30-minute settling test; SV₃₀ below 1 000 mL/L (at 1 000 nothing has settled and the implied return ratio is infinite).

References

  • SVI = SV₃₀ (mL/L) × 1000 / MLSS (mg/L) (Standard Methods 2710 D)

Questions and answers

300 mL/L settled at 3000 mg/L MLSS?

SVI 100 mL/g, on the line between good and fair; the page puts exactly 100 in the fair band (good is below 100).

High SVI?

Bulking sludge, often filamentous organisms.

Return ratio?

About 0.43 from the settled volume here.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.