Worked example
Example: 20 mg/L NO3-N, 1 NO2-N, 2 DO. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 10,000 m³/d |
| Nitrate nitrogen removed | 20.000 mg/L |
| Nitrite nitrogen removed | 1.0000 mg/L |
| Dissolved oxygen entering | 2.0000 mg/L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Methanol concentration needed | 52.670 mg/L |
| Methanol dose | 526.70 kg/d |
| Methanol volume (0.791 kg/L) | 27.744 L/h |
| Biomass produced | 11.300 mg/L |
| Alkalinity recovered (as CaCO₃) | 74.970 mg/L |
Open this example in the calculator and change any input.
Formula
\(C_m = 2.47\,NO_3\text{-}N + 1.53\,NO_2\text{-}N + 0.87\,DO, \quad C_b = 0.53\,NO_3\text{-}N + 0.32\,NO_2\text{-}N + 0.19\,DO\) \(\dot m = C_m Q, \quad \dot V = \frac{\dot m}{791\ \mathrm{kg/m^3}}, \quad Alk = 3.57\,(NO_3\text{-}N + NO_2\text{-}N)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Flow | m³/s |
| \(NO_3\text{-}N\) | Nitrate nitrogen removed | kg/m³ |
| \(NO_2\text{-}N\) | Nitrite nitrogen removed | kg/m³ |
| \(DO\) | Dissolved oxygen entering | kg/m³ |
| \(C_m\) | Methanol concentration needed | kg/m³ |
| \(\dot m_{CH_3OH}\) | Methanol dose | kg/s |
| \(\dot V\) | Methanol volume (0.791 kg/L) | m³/s |
| \(C_b\) | Biomass produced | kg/m³ |
| \(Alk\) | Alkalinity recovered (as CaCO₃) | kg/m³ |
Method and standards
McCarty's equations.
Where it is used
- Tertiary denitrification filters.
- Nitrate removal from industrial effluent.
Common mistakes
- Ignoring DO in the feed.
- Overdosing and raising effluent BOD.
Assumptions and limits
- Methanol as the carbon source; methanol density 0.791 kg/L.
- Alkalinity recovered at 3.57 g as CaCO₃ per g of nitrate or nitrite nitrogen reduced (the denitrification stoichiometry given in Metcalf & Eddy).
References
- McCarty
- Beck and St. Amant (1969)
- Proc. 24th Industrial Waste Conf.
- Purdue; Metcalf & Eddy
- Wastewater Engineering: Treatment and Resource Recovery
- 5th ed. (McGraw-Hill, 2014)
- ch. 7
Questions and answers
Why include dissolved oxygen?
Oxygen entering the anoxic zone is used first and consumes methanol without removing nitrate.
Is methanol the only carbon source?
No: acetate, glycerol, molasses or the plant's own BOD also work, with different ratios.
What do the defaults give?
20 mg/L nitrate-N, 1 mg/L nitrite and 2 mg/L DO at 10,000 m³/d: 52.7 mg/L methanol, 527 kg/d.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.