Worked example
Example: Sugar effluent 1000 m3/d, 6000 mg/L. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wastewater flow | 1,000.0 m³/d |
| Influent COD | 6,000.0 mg/L |
| Design organic loading rate | 10.000 kg/(m³·d) |
| Minimum hydraulic retention time | 8.0000 h |
| Design upflow velocity | 0.80000 m/h |
| COD removal | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volume by organic loading | 600.00 m³ |
| Volume by retention time | 333.33 m³ |
| Governing volume | 600.00 m³ |
| Area for the upflow velocity | 52.083 m² |
| Reactor liquid height | 11.520 m |
| Methane at 0.35 Nm³/kg COD removed | 1,680.0 Nm³/d |
Open this example in the calculator and change any input.
Formula
\(V_{OLR} = \frac{Q\,COD}{OLR}, \quad V_{HRT} = Q\,HRT, \quad A = \frac{Q}{v_{up}}, \quad H = \frac{V}{A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Wastewater flow | m³/s |
| \(COD\) | Influent COD | kg/m³ |
| \(OLR\) | Design organic loading rate | kg/(m³·s) |
| \(HRT_{min}\) | Minimum hydraulic retention time | s |
| \(v_{up}\) | Design upflow velocity | m/s |
| \(\eta\) | COD removal | - |
| \(V_{OLR}\) | Volume by organic loading | m³ |
| \(V_{HRT}\) | Volume by retention time | m³ |
| \(V\) | Governing volume | m³ |
| \(A\) | Area for the upflow velocity | m² |
| \(H\) | Reactor liquid height | m |
| \(CH_4\) | Methane at 0.35 Nm³/kg COD removed | Nm³/s |
Method and standards
Design definitions.
Where it is used
- Sugar, distillery, dairy and food effluent treatment.
Common mistakes
- Using peak flow for OLR and average for upflow (check both at peak).
- Ignoring sulfate (H₂S) in methane estimates.
Assumptions and limits
- Granular sludge; mesophilic.
References
- Metcalf & Eddy
- Wastewater Engineering: Treatment and Resource Recovery
- 5th ed. (McGraw-Hill, 2014)
- ch. 10 (UASB design: organic loading, upflow velocity, height)
- Lettinga and Hulshoff Pol (1991)
- Water Sci. Technol. 24(8): 87
Questions and answers
Which limit governs?
Organic loading for strong wastes (distillery, sugar, dairy); retention time and upflow velocity for weak ones like sewage.
Why limit upflow velocity?
Too fast washes out the sludge blanket; too slow gives poor contact and a tall, narrow reactor.
What do the defaults give?
1,000 m³/d at 6,000 mg/L COD and 10 kg/(m³·d): 600 m³, 52 m² at 0.8 m/h, 11.5 m high: split into reactors.