UASB Reactor Sizing: Volume, Area and Height

UASB anaerobic reactor volume from organic loading rate and retention time, area from upflow velocity, liquid height and methane from COD removed.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Sugar effluent 1000 m3/d, 6000 mg/LWeak effluent 2000 m3/d, 1500 mg/L

Results

The height is outside the usual 4–7 m: adjust the upflow velocity or split into more reactors.

Lettinga's guidance: OLR 5–15 kg COD/(m³·d) at 30 °C for granular sludge, upflow 0.5–1 m/h, height 4.5–6 m; methane at 0.35 Nm³ per kg COD removed (theoretical, before sulfate reduction and growth).

Volume by organic loading600.00m³
Volume by retention time333.33m³
Governing volume600.00m³
Area for the upflow velocity52.083m²
Reactor liquid height11.520m
Methane at 0.35 Nm³/kg COD removed1,680.0Nm³/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sugar effluent 1000 m3/d, 6000 mg/L. The inputs, in the units selected above:

InputValue
Wastewater flow1,000.0 m³/d
Influent COD6,000.0 mg/L
Design organic loading rate10.000 kg/(m³·d)
Minimum hydraulic retention time8.0000 h
Design upflow velocity0.80000 m/h
COD removal80.000 %

Applying the formula below gives:

ResultValue
Volume by organic loading600.00 m³
Volume by retention time333.33 m³
Governing volume600.00 m³
Area for the upflow velocity52.083 m²
Reactor liquid height11.520 m
Methane at 0.35 Nm³/kg COD removed1,680.0 Nm³/d

Open this example in the calculator and change any input.

Formula

\(V_{OLR} = \frac{Q\,COD}{OLR}, \quad V_{HRT} = Q\,HRT, \quad A = \frac{Q}{v_{up}}, \quad H = \frac{V}{A}\)

Variables

Symbol Meaning SI unit
\(Q\) Wastewater flow m³/s
\(COD\) Influent COD kg/m³
\(OLR\) Design organic loading rate kg/(m³·s)
\(HRT_{min}\) Minimum hydraulic retention time s
\(v_{up}\) Design upflow velocity m/s
\(\eta\) COD removal -
\(V_{OLR}\) Volume by organic loading m³
\(V_{HRT}\) Volume by retention time m³
\(V\) Governing volume m³
\(A\) Area for the upflow velocity m²
\(H\) Reactor liquid height m
\(CH_4\) Methane at 0.35 Nm³/kg COD removed Nm³/s

Method and standards

Design definitions.

Where it is used

  • Sugar, distillery, dairy and food effluent treatment.

Common mistakes

  • Using peak flow for OLR and average for upflow (check both at peak).
  • Ignoring sulfate (H₂S) in methane estimates.

Assumptions and limits

  • Granular sludge; mesophilic.

References

  • Metcalf & Eddy
  • Wastewater Engineering: Treatment and Resource Recovery
  • 5th ed. (McGraw-Hill, 2014)
  • ch. 10 (UASB design: organic loading, upflow velocity, height)
  • Lettinga and Hulshoff Pol (1991)
  • Water Sci. Technol. 24(8): 87

Questions and answers

Which limit governs?

Organic loading for strong wastes (distillery, sugar, dairy); retention time and upflow velocity for weak ones like sewage.

Why limit upflow velocity?

Too fast washes out the sludge blanket; too slow gives poor contact and a tall, narrow reactor.

What do the defaults give?

1,000 m³/d at 6,000 mg/L COD and 10 kg/(m³·d): 600 m³, 52 m² at 0.8 m/h, 11.5 m high: split into reactors.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.