FireCADCalc

Biogas Energy and Power from Volume and Methane Content

Energy and electrical output from a daily biogas volume, its methane content and the methane heating value, with an engine or boiler efficiency.

Sugar mill and cogenerationChemical and fertiliserFood, dairy and textile

Inputs

Examples: 2000 Nm3/d at 60 %Distillery 15 000 Nm3/d at 55 %

About 35.8 MJ/Nm³ at 0 °C, 1 atm; your reference.

Results

Fuel energy per day42.960GJ
Average electrical output188.94kW
Average recoverable heat198.89kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2000 Nm3/d at 60 %. The inputs, in the units selected above:

InputValue
Biogas per day (normal)2,000.0 Nm³/d
Methane volume fraction60.000 %
Methane lower heating value35.800 MJ/Nm³
Engine electrical efficiency38.000 %
Recoverable heat efficiency40.000 %

Applying the formula below gives:

ResultValue
Fuel energy per day42.960 GJ
Average electrical output188.94 kW
Average recoverable heat198.89 kW

Open this example in the calculator and change any input.

Formula

\(\dot E = \dot V x_{CH_4} LHV, \quad P_e = \eta_e \dot E\)

Variables

Symbol Meaning SI unit
\(V\) Biogas per day (normal) Nm³/s
\(x_{CH_4}\) Methane volume fraction -
\(LHV\) Methane lower heating value J/m³
\(\eta_e\) Engine electrical efficiency -
\(\eta_h\) Recoverable heat efficiency -
\(E\) Fuel energy per day J
\(P_e\) Average electrical output W
\(P_h\) Average recoverable heat W

Method and standards

Energy balance.

Where it is used

  • ETP and distillery biogas.
  • Waste-to-energy screening.

Common mistakes

  • Actual instead of normal volume.
  • HHV with LHV efficiencies.

Assumptions and limits

  • Steady gas production.
  • Electrical plus recoverable heat efficiency may not exceed 100 %.

References

  • Energy = V × x_CH₄ × LHV_CH₄

Questions and answers

2000 Nm³/day at 60 % methane?

About 43.0 GJ a day: 189 kW electrical at 38 %.

H₂S?

Remove it before engines; it corrodes them.

Distillery or ETP biogas?

Yield depends on COD removed; measure the gas.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.