Worked example
Example: 100 m rotor at 9 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air density | 1.2250 kg/m³ |
| Rotor diameter | 100.00 m |
| Wind speed at hub height | 9.0000 m/s |
| Power coefficient (turbine and drive) | 42.000 % |
| Capacity factor (for annual energy) | 30.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Swept area | 7,854.0 m² |
| Power in the wind ½ρAv³ | 3.5069 MW |
| Betz-limit power (16/27) | 2.0782 MW |
| Turbine output at C_p | 1.4729 MW |
| Annual energy at the capacity factor | 3,870.8 MWh |
Open this example in the calculator and change any input.
Formula
\(P = \frac{1}{2}\rho A v^3 C_p, \quad C_{p,max} = \frac{16}{27}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Air density | kg/m³ |
| \(D\) | Rotor diameter | m |
| \(v\) | Wind speed at hub height | m/s |
| \(C_p\) | Power coefficient (turbine and drive) | - |
| \(CF\) | Capacity factor (for annual energy) | - |
| \(A\) | Swept area | m² |
| \(P_w\) | Power in the wind ½ρAv³ | W |
| \(P_{Betz}\) | Betz-limit power (16/27) | W |
| \(P\) | Turbine output at C_p | W |
| \(E\) | Annual energy at the capacity factor | J |
Method and standards
Actuator disc.
Where it is used
- Captive wind projects.
- Teaching and examinations.
Common mistakes
- Mean speed cubed instead of the mean of cubes.
- Ground-level wind speed.
Assumptions and limits
Annual energy = P × CF × 8 760 h (a 365-day year): the output at one wind speed scaled by a capacity factor, not an integral over a power curve and wind distribution. The Weibull wind energy calculator does that, with a 365.25-day year, so its CF means the long-term average output over rated power.
Steady uniform wind.
References
- P = ½ρAv³C_p; Betz (1920) limit C_p ≤ 16/27
Questions and answers
100 m rotor at 9 m/s, C_p 0.42?
About 1.47 MW.
Why does wind speed matter so much?
Power goes with the cube: 10 % more wind gives 33 % more power.
Betz limit?
No turbine can extract more than 16/27 (59.3 %) of the wind's power.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.