Worked example
Example: Improved SEC. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Baseline energy | 520,000 GJ |
| Baseline production | 100,000 - |
| Current energy | 540,000 GJ |
| Current production | 112,000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Baseline SEC (energy per unit of product) | 5.2000 GJ |
| Current SEC (energy per unit of product) | 4.8214 GJ |
| Improvement | 7.2802 % |
| Energy saved at current production | 42,400 GJ |
Open this example in the calculator and change any input.
Formula
\(SEC = \frac{E}{P}, \quad E_s = (SEC_0 - SEC_1)P_1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_0\) | Baseline energy | J |
| \(P_0\) | Baseline production | - |
| \(E_1\) | Current energy | J |
| \(P_1\) | Current production | - |
| \(SEC_0\) | Baseline SEC (energy per unit of product) | J per unit |
| \(SEC_1\) | Current SEC (energy per unit of product) | J per unit |
| \(\Delta SEC\) | Improvement | - |
| \(E_s\) | Energy saved at current production | J |
Method and standards
Ratio method.
Where it is used
- Energy management systems.
- PAT and ISO 50001 reporting.
Common mistakes
- Not normalising.
- Mixing energy units.
Assumptions and limits
- Comparable operating conditions; simple ratio method without regression normalisation (ISO 50006 baselines).
- SEC is energy per unit of product in the same energy unit as the inputs.
References
- SEC = energy/production; saving = (SEC₀ − SEC₁) × P₁ (ISO 50006 EnPI principle)
Questions and answers
520,000 GJ for 100,000 t, then 540,000 GJ for 112,000 t?
SEC 5.20 → 4.82 GJ/t: 7.3 % better, about 42,400 GJ saved.
Why not compare total energy?
Production rose; energy per unit shows real improvement.
PAT scheme?
Uses SEC with normalisation rules of its own.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.