Worked example
Example: 50,000 t/yr for 20 years, year 25. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Waste accepted per year (t) | 50,000 - |
| Years of acceptance | 20.000 - |
| Year of interest (from opening) | 25.000 - |
| Decay rate (per year) | 0.050000 - |
| Methane potential (m³/t) | 100.00 - |
| Methane fraction of landfill gas | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Methane generation | 280.80 m³/h |
| Landfill gas generation | 561.60 m³/h |
| Methane energy (LHV 35.8 MJ/m³) | 2.7924 MW |
Open this example in the calculator and change any input.
Formula
\(Q_{CH_4}(t) = L_0M\left[e^{-k(t - n)} - e^{-kt}\right]\ (t > n), \quad L_0M(1 - e^{-kt})\ (t \le n)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Waste accepted per year (t) | - |
| \(n\) | Years of acceptance | - |
| \(t\) | Year of interest (from opening) | - |
| \(k\) | Decay rate (per year) | - |
| \(L_0\) | Methane potential (m³/t) | - |
| \(f_{CH_4}\) | Methane fraction of landfill gas | - |
| \(Q_{CH_4}\) | Methane generation | m³/s |
| \(Q_{LFG}\) | Landfill gas generation | m³/s |
| \(P\) | Methane energy (LHV 35.8 MJ/m³) | W |
Method and standards
First-order decay.
Where it is used
- Landfill gas engine sizing.
- Methane emission estimates.
Common mistakes
- Expecting all gas to be collected.
- Using dry-site k for wet climates.
Assumptions and limits
- Constant acceptance; single decay rate. The continuous form differs slightly from LandGEM's 0.1-year discrete summation; M and n are used as entered (n may be fractional).
- L₀ and the methane flow are taken at the reference state of the 35.8 MJ/m³ heating value (0 °C, 1 atm); if L₀ is quoted at LandGEM's 25 °C reference, the energy here is about 9 % high.
References
- First-order decay Q = kL₀M e^(−kt)
- US EPA LandGEM user's manual (2005)
Questions and answers
Why does generation peak at closure?
Fresh waste keeps adding gas while earlier waste decays; once acceptance stops, generation falls exponentially.
What does k depend on?
Moisture and temperature: dry sites about 0.02 per year, wet or tropical sites 0.1–0.2.
What do the defaults represent?
50,000 t a year for 20 years, five years after closure.