Worked example
Example: Coal fired, 90 % control. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Activity per year (fuel burnt, product made…) | 250,000 - |
| Emission factor (kg per unit of activity) | 9.5000 - |
| Control efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Uncontrolled emission | 2,375.0 t |
| Controlled emission | 237.50 t |
Open this example in the calculator and change any input.
Formula
\(E = A \cdot EF \cdot (1 - \eta_c)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Activity per year (fuel burnt, product made…) | - |
| \(EF\) | Emission factor (kg per unit of activity) | - |
| \(\eta_c\) | Control efficiency | - |
| \(E_0\) | Uncontrolled emission | kg |
| \(E\) | Controlled emission | kg |
Method and standards
Inventory method.
Where it is used
- Annual environmental statements.
- Permit applications.
Common mistakes
- Factor units mismatched.
- Control efficiency applied twice.
Assumptions and limits
- Average annual conditions.
- EF in kg per unit of activity: convert AP-42 factors first (1 lb per short ton = 0.5 kg/t; 1 lb/MMBtu = 0.430 kg/GJ), or the result is off by a factor of 2 or more.
References
- E = A × EF × (1 − η_c) (emission inventory method, e.g. US EPA AP-42 introduction)
Questions and answers
250,000 t of fuel at 9.5 kg/t with 90 % control?
2,375 t uncontrolled, 238 t emitted.
Factor or measurement?
Measurements beat factors when you have them.
Units?
The activity unit must match the factor's.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.