Stack Gas Moisture by Condensation (EPA Method 4)

Moisture fraction of stack gas from water collected in impingers and silica gel and the dry gas metered (EPA Method 4), checked against saturation.

Thermal power plantSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperIAPWS-IF97 (water and steam)

Inputs

Examples: 45.2 g against 0.85 m3, 60 °C stackWet scrubber stack 50 °C with droplets

Results

Water vapour at 20 °C, 101.325 kPa60.355L
Dry gas at 20 °C, 101.325 kPa828.94L
Moisture fraction measured6.7868%
Moisture at saturation (stack conditions)19.946%
Moisture to report (the lower)6.7868%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 45.2 g against 0.85 m3, 60 °C stack. The inputs, in the units selected above:

InputValue
Water collected (impingers plus silica gel)45.200 g
Dry gas metered850.00 L
Dry gas meter calibration factor1.0000 -
Meter temperature25.000 °C
Meter pressure (absolute)100.50 kPa
Stack temperature60.000 °C
Stack pressure (absolute)100.00 kPa

Applying the formula below gives:

ResultValue
Water vapour at 20 °C, 101.325 kPa60.355 L
Dry gas at 20 °C, 101.325 kPa828.94 L
Moisture fraction measured6.7868 %
Moisture at saturation (stack conditions)19.946 %
Moisture to report (the lower)6.7868 %

Open this example in the calculator and change any input.

Formula

\(V_{w,std} = \frac{m_w}{M_w}\frac{RT_{std}}{p_{std}}, \quad V_{m,std} = V_mY\frac{T_{std}}{T_m}\frac{p_m}{p_{std}}, \quad B_{ws} = \frac{V_{w,std}}{V_{w,std} + V_{m,std}}\)

Variables

Symbol Meaning SI unit
\(m_w\) Water collected (impingers plus silica gel) kg
\(V_m\) Dry gas metered m³
\(Y\) Dry gas meter calibration factor -
\(T_m\) Meter temperature K
\(p_m\) Meter pressure (absolute) Pa
\(T_s\) Stack temperature K
\(p_s\) Stack pressure (absolute) Pa
\(V_{w,std}\) Water vapour at 20 °C, 101.325 kPa m³
\(V_{m,std}\) Dry gas at 20 °C, 101.325 kPa m³
\(B_{ws}\) Moisture fraction measured -
\(B_{ws,sat}\) Moisture at saturation (stack conditions) -
\(B_{ws,rep}\) Moisture to report (the lower) -
\(M_w\) Molar mass of water, 18.015 kg/kmol
\(R\) Universal gas constant, 8.314 462 618 J/(mol·K)
\(T_{std}, p_{std}\) Standard conditions, 293.15 K and 101 325 Pa K, Pa

Method and standards

EPA Method 4 calculations in SI.

Where it is used

  • Stack testing and emission reporting.
  • Wet–dry concentration conversion.

Common mistakes

  • Leaving out the silica gel gain.
  • Using gauge meter pressure.

Assumptions and limits

  • Ideal gas; standard conditions 20 °C, 101.325 kPa.

References

  • US EPA Method 4
  • 40 CFR Part 60 Appendix A-3 (determination of moisture content in stack gases)
  • standard conditions 20 °C and 101.325 kPa; IAPWS-IF97 saturation pressure

Questions and answers

Why compare with saturation?

Droplets in a wet stack add water the gas does not actually carry as vapour; EPA requires the lower of the measured and saturation values.

Where does the water come from?

Impinger liquid gain plus the silica gel weight gain.

What do the defaults give?

45.2 g of water against 0.85 m³ of dry gas: about 6.8 % moisture, well below saturation at 60 °C.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.