Worked example
Example: Dust 50 mg/Nm3 at 150 000 Nm3/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Concentration (same basis as the flow) | 50.000 mg/Nm³ |
| Flue gas flow (normal, same basis) | 150,000 Nm³/h |
| Operating hours per year | 8,000.0 h |
| Fuel heat input, GCV or NCV basis as your limit uses (0 to skip) | 120.00 MW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Emission rate | 7.5000 kg/h |
| Annual emission | 60.000 t |
| Emission per heat input | 17.361 g/GJ |
Open this example in the calculator and change any input.
Formula
\(\dot E = C\,\dot V_N, \quad E_y = \dot E\, t, \quad e = \frac{\dot E}{\dot Q_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Concentration (same basis as the flow) | kg/m³ |
| \(\dot V_N\) | Flue gas flow (normal, same basis) | Nm³/s |
| \(t\) | Operating hours per year | s |
| \(\dot Q_f\) | Fuel heat input, GCV or NCV basis as your limit uses (0 to skip) | W |
| \(\dot E\) | Emission rate | kg/s |
| \(E_y\) | Annual emission | kg |
| \(e\) | Emission per heat input | kg/J |
Method and standards
Mass flow.
Where it is used
- Emission reporting and permits.
- Comparing with limits per GJ.
Common mistakes
- Mixing dry concentration with wet flow.
- Actual instead of normal flow.
Assumptions and limits
- Steady emission.
- The emission per heat input follows the basis of the heat input entered (gross or net calorific value); regulatory g/GJ limits differ by basis. With the heat input left at 0 it is not shown.
References
- Mass flow = concentration × normal volume flow
Questions and answers
50 mg/Nm³ of dust in 150,000 Nm³/h?
7.5 kg/h, 60 t a year at 8000 h.
Per GJ?
About 17.4 g/GJ for 120 MW of fuel.
Different bases?
Convert wet to dry and correct to the reference O₂ before multiplying.