Worked example
Example: 60 m boiler stack, 150 °C, 4 m/s wind. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Physical stack height | 60.000 m |
| Stack exit diameter | 2.5000 m |
| Exit velocity | 15.000 m/s |
| Exit gas temperature | 150.00 °C |
| Ambient temperature | 30.000 °C |
| Wind speed at stack top | 4.0000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Buoyancy flux (m⁴/s³) | 65.181 |
| Distance to final rise | 632.70 m |
| Final plume rise | 118.64 m |
| Effective stack height | 178.64 m |
Open this example in the calculator and change any input.
Formula
\(F_b = gv_sd^2\frac{T_s - T_a}{4T_s}, \quad \Delta h = \frac{1.6F_b^{1/3}x_f^{2/3}}{u}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h_s\) | Physical stack height | m |
| \(d\) | Stack exit diameter | m |
| \(v_s\) | Exit velocity | m/s |
| \(T_s\) | Exit gas temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(u\) | Wind speed at stack top | m/s |
| \(F_b\) | Buoyancy flux (m⁴/s³) | - |
| \(x_f\) | Distance to final rise | m |
| \(\Delta h\) | Final plume rise | m |
| \(H\) | Effective stack height | m |
Method and standards
Briggs buoyant rise.
Where it is used
- Stack design and dispersion screening.
- Effect of flue gas temperature on dispersion.
Common mistakes
- Using stable-air conditions with this form.
- Ignoring downwash.
Assumptions and limits
- Buoyancy-dominated plume; neutral or unstable air. Stable air gives a lower rise, not computed here.
- A temperature excess below the Briggs crossover ΔT_c (momentum-dominated plume) and stack-tip downwash (v_s < 1.5u) are flagged.
References
- Briggs (1975) plume rise equations as used in US EPA dispersion models (de Nevers, Air Pollution Control Engineering, 2nd ed. (McGraw-Hill, 2000), ch. 6)
Questions and answers
Why does plume rise matter?
Ground-level concentration falls roughly with the square of effective height; rise often adds as much as the stack itself.
Why does wind lower the rise?
Stronger wind bends the plume over faster, so it rises less before levelling off.
What do the defaults represent?
A 60 m boiler stack, 2.5 m diameter, 15 m/s at 150 °C in a 4 m/s wind.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.