Worked example
Example: Boiler stack 15 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Stack gas velocity at the point | 15.000 m/s |
| Nozzle diameter | 6.0000 mm |
| Stack gas temperature | 140.00 °C |
| Stack pressure (absolute) | 100.00 kPa |
| Gas meter temperature | 25.000 °C |
| Gas meter pressure (absolute) | 99.000 kPa |
| Stack moisture (removed before the meter) | 10.000 % |
| Target meter flow (for nozzle choice) | 15.000 L/min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Sample flow at stack conditions | 25.447 L/min |
| Dry flow at the meter | 16.694 L/min |
| Nozzle for the target meter flow | 5.6874 mm |
Open this example in the calculator and change any input.
Formula
\(\dot V_s = v_s\frac{\pi d_n^2}{4}, \quad \dot V_m = \dot V_s\frac{T_m}{T_s}\cdot\frac{p_s}{p_m}(1 - B_{ws})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v_s\) | Stack gas velocity at the point | m/s |
| \(d_n\) | Nozzle diameter | m |
| \(T_s\) | Stack gas temperature | K |
| \(p_s\) | Stack pressure (absolute) | Pa |
| \(T_m\) | Gas meter temperature | K |
| \(p_m\) | Gas meter pressure (absolute) | Pa |
| \(B_{ws}\) | Stack moisture (removed before the meter) | - |
| \(\dot V_t\) | Target meter flow (for nozzle choice) | m³/s |
| \(\dot V_s\) | Sample flow at stack conditions | m³/s |
| \(\dot V_m\) | Dry flow at the meter | m³/s |
| \(d_t\) | Nozzle for the target meter flow | m |
Method and standards
Continuity and ideal gas.
Where it is used
- Stack dust monitoring.
- ESP and bag filter performance tests.
Common mistakes
- Using meter flow without temperature correction.
- Ignoring moisture removal.
Assumptions and limits
- Ideal gas.
References
- Isokinetic condition and ideal-gas correction to meter conditions (EPA Method 5 principle; ISO 9096)
Questions and answers
15 m/s, 6 mm nozzle, 140 °C, 10 % moisture?
About 16.7 L/min dry at the meter.
Why isokinetic?
Too slow over-samples coarse dust, too fast under-samples it.
Changing velocity across the duct?
Re-set the flow at each traverse point.