Worked example
Example: S-type pitot 250 Pa, Cp 0.84, 140 °C, 99.5 kPa, M 29.5, stack 2.5 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Average velocity pressure (pitot reading) | 250.00 Pa |
| Pitot tube coefficient | 0.84000 - |
| Gas temperature | 140.00 °C |
| Gas pressure in the stack (absolute) | 0.99500 bar |
| Molar mass of the wet gas | 29.500 kg/kmol |
| Stack inside diameter | 2.5000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas velocity | 20.319 m/s |
| Actual volume flow | 359,075 m³/h |
| Flow at normal conditions (wet) | 233,123 Nm³/h |
| Gas density in the stack | 0.85448 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\rho = \frac{p\,M}{R\,T} \qquad v = C_p\sqrt{\frac{2\,\Delta p}{\rho}} \qquad \dot V = v\,\frac{\pi D^2}{4} \qquad \dot V_n = \dot V\,\frac{p}{p_n}\,\frac{T_n}{T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\Delta p\) | velocity pressure | Pa |
| \(C_p\) | pitot coefficient | – |
| \(T\) | gas temperature | K |
| \(p\) | gas pressure | Pa |
| \(M\) | molar mass of the wet gas | kg/kmol |
| \(D\) | stack diameter | m |
| \(v\) | velocity | m/s |
| \(\dot V\) | actual flow | m³/s |
| \(\dot V_n\) | flow at normal conditions | Nm³/s |
| \(\rho\) | gas density | kg/m³ |
| \(R\) | universal gas constant | J/(kmol·K) |
| \(p_n, T_n\) | 101 325 Pa and 273.15 K | Pa, K |
Method and standards
Pitot-tube equation with ideal-gas density, the principle behind US EPA Method 2; flow at normal conditions by the ideal-gas law.
Where it is used
- Stack emission testing.
- Checking fan and ID fan flows.
- Calibrating continuous flow monitors.
Common mistakes
- Single-point readings instead of a traverse.
- Using dry molar mass for wet gas.
- Ignoring cyclonic flow in the stack.
Assumptions and limits
- Ideal gas; uniform flow across each traverse point.
- The normal flow is on a wet basis; for emission reporting convert to dry gas (multiply by 1 − the water vapour fraction) and to the reference O₂ separately.
References
- Pitot-tube velocity equation
- the principle of US EPA Method 2
Questions and answers
How fast does the stack gas move?
A velocity pressure of 250 Pa on an S-type pitot (Cp 0.84) in gas at 140 °C, 99.5 kPa and molar mass 29.5 gives 20.3 m/s; in a 2.5 m stack that is 99.7 m³/s, 64.8 Nm³/s.
Why average the square roots?
Velocity goes with the square root of the velocity pressure; averaging the pressures first overstates the mean velocity.
Which coefficient?
The calibrated value of your pitot; S-type tubes are about 0.84, standard (Prandtl) tubes about 0.99.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.