Worked example
Example: Water 20 °C, DN100 (102.3 mm), bore 60 mm, 250 mbar, flange taps. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pipe inside diameter | 102.30 mm |
| Orifice bore | 60.000 mm |
| Pressure tappings | Flange |
| Differential pressure | 250.00 mbar |
| Upstream pressure (absolute) | 5.0000 bar |
| Density at the upstream tapping | 998.20 kg/m³ |
| Dynamic viscosity | 1.0020 cP |
| Isentropic exponent (0 = liquid) | 0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mass flow | 46,627 kg/h |
| Volume flow at upstream conditions | 46.711 m³/h |
| Discharge coefficient | 0.60884 |
| Expansibility factor | 1.0000 |
| Diameter ratio d/D | 0.58651 |
| Pipe Reynolds number | 160,880 |
| Permanent pressure loss | 160.61 mbar |
Open this example in the calculator and change any input.
Formula
\(q_m = \frac{C}{\sqrt{1-\beta^4}}\;\varepsilon\;\frac{\pi}{4}d^2\sqrt{2\,\Delta p\,\rho_1} \qquad \beta = \frac{d}{D} \qquad Re_D = \frac{4\,q_m}{\pi\,\mu\,D} \qquad q_V = \frac{q_m}{\rho_1}\)
Reader-Harris/Gallagher equation, with \(A = (19000\beta/Re_D)^{0.8}\) and \(M_2' = 2L_2'/(1-\beta)\):
\(C = 0.5961 + 0.0261\beta^2 - 0.216\beta^8 + 0.000521\left(\frac{10^6\beta}{Re_D}\right)^{0.7} + (0.0188 + 0.0063A)\,\beta^{3.5}\left(\frac{10^6}{Re_D}\right)^{0.3}\) \(\quad + \left(0.043 + 0.080e^{-10L_1} - 0.123e^{-7L_1}\right)(1 - 0.11A)\frac{\beta^4}{1-\beta^4} - 0.031\left(M_2' - 0.8M_2'^{\,1.1}\right)\beta^{1.3}\)
plus \(0.011(0.75-\beta)(2.8 - D/25.4)\) when \(D < 71.12\) mm (\(D\) in mm). Corner taps: \(L_1 = L_2' = 0\); D and D/2: \(L_1 = 1\), \(L_2' = 0.47\); flange: \(L_1 = L_2' = 25.4/D\).
\(\varepsilon = 1 - \left(0.351 + 0.256\beta^4 + 0.93\beta^8\right)\left[1 - \left(\frac{p_1 - \Delta p}{p_1}\right)^{1/\kappa}\right] \qquad \Delta\varpi = \frac{\sqrt{1-\beta^4(1-C^2)} - C\beta^2}{\sqrt{1-\beta^4(1-C^2)} + C\beta^2}\,\Delta p\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | pipe inside diameter at flowing temperature | m |
| \(d\) | orifice bore at flowing temperature | m |
| \(\text{taps}\) | pressure tappings: corner, D and D/2, or flange | – |
| \(\Delta p\) | differential pressure | Pa |
| \(p_1\) | absolute pressure at the upstream tapping | Pa |
| \(\rho_1\) | density at the upstream tapping | kg/m³ |
| \(\mu\) | dynamic viscosity | Pa·s |
| \(\kappa\) | isentropic exponent (0 for a liquid) | – |
| \(q_m\) | mass flow | kg/s |
| \(q_V\) | volume flow at upstream conditions | m³/s |
| \(C\) | discharge coefficient | – |
| \(\varepsilon\) | expansibility factor | – |
| \(\beta\) | diameter ratio | – |
| \(Re_D\) | Reynolds number referred to the pipe diameter | – |
| \(\Delta\varpi\) | permanent pressure loss | Pa |
| \(L_1\), \(L_2'\) | tapping distances divided by \(D\) | – |
Method and standards
ISO 5167-2: mass flow equation of ISO 5167-1, discharge coefficient by the Reader-Harris/Gallagher (1998) equation, expansibility factor and pressure loss of ISO 5167-2 (equations of the 2003 edition, retained in the 2022 edition). The flow is found by iterating on the Reynolds number until the discharge coefficient converges.
Where it is used
- Sizing and checking orifice flow meters for steam, water and gas.
- Verifying a meter's range after a process change.
- Estimating flow from a measured differential pressure.
Common mistakes
- Using an orifice outside the ISO 5167 limits of diameter ratio and Reynolds number.
- Short straight lengths upstream.
- Using design density when the fluid conditions change.
Assumptions and limits
- Limits of use of ISO 5167-2, each flagged when exceeded: d ≥ 12.5 mm; 50 mm ≤ D ≤ 1 000 mm; 0.10 ≤ β ≤ 0.75; Re_D ≥ 5 000 (and ≥ 16 000β² for β > 0.56 with corner or D and D/2 taps; ≥ 170β²D[mm] with flange taps); p₂/p₁ ≥ 0.75.
- Square-edged concentric plate, single-phase flow, straight lengths as ISO 5167-2 requires.
- Diameters at flowing temperature: correct d and D for thermal expansion yourself for hot service.
- Density and viscosity are your inputs; take steam and water values from the steam and water property calculators.
References
- ISO 5167-1 (general principles)
- ISO 5167-2 (orifice plates)
- Reader-Harris/Gallagher (1998) equation
Questions and answers
How is flow through an orifice plate calculated?
q_m = C/√(1−β⁴)·ε·(π/4)d²·√(2Δp·ρ₁). For water in a 102.3 mm pipe with a 60 mm bore and 250 mbar across flange taps, C = 0.6088 and the flow is 12.95 kg/s (46.7 m³/h).
Why does the calculation iterate?
The discharge coefficient depends on the Reynolds number, which depends on the flow. The calculator repeats the calculation until the coefficient stops changing.
How much of the differential pressure is lost?
Most of it for small bores. At β = 0.59 about 64 % of the differential is not recovered: 161 mbar of the 250 mbar in the example.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.