Worked example
Example: Water, 100/200 mm, 25 kPa, C 0.995. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid | Liquid (incompressible) |
| Throat diameter | 100.00 mm |
| Pipe (inlet) diameter | 200.00 mm |
| Differential pressure | 25.000 kPa |
| Density at the inlet tapping | 998.00 kg/m³ |
| Inlet pressure, absolute (gas) | 5.0000 bar |
| Isentropic exponent (gas) | 1.4000 - |
| Discharge coefficient | 0.99500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Diameter ratio d/D | 0.50000 |
| Velocity of approach factor 1/√(1 − β⁴) | 1.0328 |
| Expansibility factor | 1.0000 |
| Mass flow | 205,249 kg/h |
| Volume flow at inlet conditions | 205.66 m³/h |
Open this example in the calculator and change any input.
Formula
\(q_m = \frac{C\, \varepsilon}{\sqrt{1 - \beta^4}} \frac{\pi}{4} d^2 \sqrt{2\, \Delta p\, \rho_1}, \quad \beta = d/D\)
\(\varepsilon = \sqrt{\frac{\kappa \tau^{2/\kappa}}{\kappa - 1} \cdot \frac{1 - \beta^4}{1 - \beta^4 \tau^{2/\kappa}} \cdot \frac{1 - \tau^{(\kappa-1)/\kappa}}{1 - \tau}}, \quad \tau = \frac{p_1 - \Delta p}{p_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{fluid}\) | Fluid | - |
| \(d\) | Throat diameter | m |
| \(D\) | Pipe (inlet) diameter | m |
| \(\Delta p\) | Differential pressure | Pa |
| \(\rho_1\) | Density at the inlet tapping | kg/m³ |
| \(p_1\) | Inlet pressure, absolute (gas) | Pa |
| \(\kappa\) | Isentropic exponent (gas) | - |
| \(C\) | Discharge coefficient | - |
| \(\beta\) | Diameter ratio d/D | - |
| \(E\) | Velocity of approach factor 1/√(1 − β⁴) | - |
| \(\varepsilon\) | Expansibility factor | - |
| \(q_m\) | Mass flow | kg/s |
| \(q_V\) | Volume flow at inlet conditions | m³/s |
| \(\tau\) | Pressure ratio (p₁ − Δp)/p₁ | - |
Method and standards
The differential-pressure flow equation of ISO 5167 with the isentropic expansibility used for venturi tubes and nozzles; the discharge coefficient is entered for your construction or from calibration.
Where it is used
- Cooling water, feedwater and air flow measurement.
- Checking a venturi's DP transmitter range.
- Comparing venturi and orifice meters.
Common mistakes
- Using the orifice expansibility formula for a venturi.
- Using downstream density.
- Using the throat diameter at the wrong temperature.
Assumptions and limits
- Full pipe, steady flow; ISO 5167-4 limits on β and Reynolds number.
- The discharge coefficient is entered, not computed, and there is no viscosity input, so the Reynolds number is not checked: confirm that the pipe Reynolds number lies in the range ISO 5167-4 gives for your construction (or in the calibration range), otherwise the entered C does not apply. β and the gas pressure ratio are checked.
References
- ISO 5167-4 classical venturi tubes (method)
Questions and answers
What flow does a 100/200 mm venturi give at 25 kPa on water?
With C 0.995, 57.0 kg/s, about 205 m³/h.
How does a gas change it?
The expansibility factor: air at 5 bar(a) with 40 kPa drop has ε = 0.953, so the flow is 4.7 % below the liquid formula.
Why use a venturi instead of an orifice?
Much lower permanent pressure loss and less wear, at higher cost and length.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.