FireCADCalc

Ultrasonic Transit-Time Flowmeter Velocity and Flow

Flow velocity and volume flow from the upstream and downstream transit times of an ultrasonic flowmeter, the path length and the path angle.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 152.0 / 151.6 µs, 226 mm path at 45°, DN150Water, 300 mm pipe, 60°, 0.4 µs differenceGas 1.2 m path at 45°, 3 ms and 2.94 ms

Depends on Reynolds number: 0.75 for laminar flow, about 0.93–0.96 for turbulent flow in a straight pipe.

Results

The speed of sound cancels out of the velocity, so the result does not depend on fluid temperature.

Velocity along the path axis2.7777m/s
Speed of sound in the fluid1,490.8m/s
Mean velocity in the pipe2.6110m/s
Volume flow188.99m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 152.0 / 151.6 µs, 226 mm path at 45°, DN150. The inputs, in the units selected above:

InputValue
Transit time upstream (against the flow)1.5200e-04 s
Transit time downstream (with the flow)1.5160e-04 s
Acoustic path length226.30 mm
Angle of the path to the pipe axis45.000 °
Pipe inside diameter160.00 mm
Profile factor (mean / path velocity)0.94000 -

Applying the formula below gives:

ResultValue
Velocity along the path axis2.7777 m/s
Speed of sound in the fluid1,490.8 m/s
Mean velocity in the pipe2.6110 m/s
Volume flow188.99 m³/h

Open this example in the calculator and change any input.

Formula

\(v_L = \frac{L}{2\cos\theta}\, \frac{t_{up} - t_{dn}}{t_{up}\, t_{dn}}, \quad c = \frac{L}{2}\, \frac{t_{up} + t_{dn}}{t_{up}\, t_{dn}}, \quad Q = k_h v_L \frac{\pi D^2}{4}\)

Variables

Symbol Meaning SI unit
\(t_{up}\) Transit time upstream (against the flow) s
\(t_{dn}\) Transit time downstream (with the flow) s
\(L\) Acoustic path length m
\(\theta\) Angle of the path to the pipe axis rad
\(D\) Pipe inside diameter m
\(k_h\) Profile factor (mean / path velocity) -
\(v_L\) Velocity along the path axis m/s
\(c\) Speed of sound in the fluid m/s
\(v_m\) Mean velocity in the pipe m/s
\(Q\) Volume flow m³/s

Method and standards

Sound travels faster with the flow than against it.

Where it is used

  • Clamp-on surveys of water and condensate.
  • Checking meter configuration.

Common mistakes

  • Wrong path length or angle.
  • Profile factor of 1 in laminar flow.

Assumptions and limits

  • The profile factor k_h is entered, not computed. For a diametral single path it is 0.75 in laminar flow and rises to about 0.93–0.96 in turbulent flow as the Reynolds number increases; meters compute it from Re internally.

  • Single path, fully developed flow.

References

  • Transit-time principle v = L (t_up − t_dn)/(2 cos θ t_up t_dn)

Questions and answers

What velocity do 152.0 and 151.6 µs give on a 226 mm path at 45°?

2.78 m/s along the axis.

Why does temperature not matter?

Speed of sound cancels when the two times are combined this way.

What is the profile factor?

A single path sees the centre-weighted velocity; the factor converts it to the mean.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.