FireCADCalc

Dust Collectors in Series: Overall Efficiency and Outlet Load

Overall collection efficiency of up to three dust collectors in series, the outlet concentration and the dust captured from the inlet concentration and gas flow.

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Cyclone then ESPThree stages

Results

Each stage's efficiency is for the dust that reaches it; a fine-dust stage after a cyclone sees a finer, harder dust.

Overall efficiency99.925%
Outlet concentration30.000mg/Nm³
Dust captured5.9955t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cyclone then ESP. The inputs, in the units selected above:

InputValue
Collector 1 efficiency85.000 %
Collector 2 efficiency99.500 %
Collector 3 efficiency (0 if none)0 %
Inlet dust concentration40,000 mg/Nm³
Gas flow (normal)150,000 Nm³/h

Applying the formula below gives:

ResultValue
Overall efficiency99.925 %
Outlet concentration30.000 mg/Nm³
Dust captured5.9955 t/h

Open this example in the calculator and change any input.

Formula

\(\eta_o = 1 - \prod_i (1 - \eta_i), \quad C_{out} = C_{in}\prod_i(1 - \eta_i)\)

Variables

Symbol Meaning SI unit
\(\eta_1\) Collector 1 efficiency -
\(\eta_2\) Collector 2 efficiency -
\(\eta_3\) Collector 3 efficiency (0 if none) -
\(C_{in}\) Inlet dust concentration kg/m³
\(\dot V_N\) Gas flow (normal) Nm³/s
\(\eta_o\) Overall efficiency -
\(C_{out}\) Outlet concentration kg/m³
\(\dot m_c\) Dust captured kg/s

Method and standards

Penetration.

Where it is used

  • Boiler dust collection trains.
  • Compliance checks.

Common mistakes

  • Adding efficiencies.
  • Stage efficiency measured on a different dust.

Assumptions and limits

  • Independent stages: each η_i is the efficiency for the dust that actually reaches that stage. A collector after a cyclone sees finer dust, so its catalogue efficiency (quoted for the raw dust) overstates the overall result.

References

  • Penetrations multiply: 1 − η_o = Π(1 − η_i)

Questions and answers

85 % cyclone then a 99.5 % ESP on 40 g/Nm³?

Overall 99.925 %: 30 mg/Nm³ out.

Why not add efficiencies?

Each stage only sees what the previous one let through.

Does the ESP keep 99.5 %?

Not always: finer dust after a cyclone can lower it.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.