FireCADCalc

Cyclone Cut Diameter (Lapple)

Cut diameter (50 % efficiency particle size) of a cyclone by Lapple's method from gas viscosity, inlet width, inlet velocity, effective turns and particle density.

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Hot flue gas, ashAmbient air, sawdust

About 5–6 for conventional cyclones; from the design.

Results

Particles larger than d₅₀ are mostly caught, smaller ones mostly escape; the full grade-efficiency curve needs the cyclone maker's data.

Cut diameter6.1394µm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hot flue gas, ash. The inputs, in the units selected above:

InputValue
Gas viscosity2.5000e-05 Pa·s
Inlet width250.00 mm
Effective number of turns6.0000 -
Inlet velocity18.000 m/s
Particle density2,200.0 kg/m³
Gas density0.80000 kg/m³

Applying the formula below gives:

ResultValue
Cut diameter6.1394 µm

Open this example in the calculator and change any input.

Formula

\(d_{50} = \sqrt{\frac{9\mu W}{2\pi N_e V_i(\rho_p - \rho_g)}}\)

Variables

Symbol Meaning SI unit
\(\mu\) Gas viscosity Pa·s
\(W\) Inlet width m
\(N_e\) Effective number of turns -
\(V_i\) Inlet velocity m/s
\(\rho_p\) Particle density kg/m³
\(\rho_g\) Gas density kg/m³
\(d_{50}\) Cut diameter m

Method and standards

Lapple.

Where it is used

  • Mechanical dust collectors on boilers.
  • Pre-cleaners.

Common mistakes

  • Diameter instead of inlet width.
  • Cold gas viscosity for hot gas.

Assumptions and limits

  • Conventional reverse-flow cyclone.

References

  • Lapple (1951) cut diameter d₅₀ = [9μW/(2πN_eV_i(ρ_p − ρ_g))]^½

Questions and answers

250 mm inlet, 18 m/s, six turns, ash at 2200 kg/m³, hot gas?

d₅₀ about 6.1 µm.

How to lower d₅₀?

Narrower inlet, higher velocity or more turns, at more pressure drop.

Fine fly ash?

Cyclones miss most particles below about 5 µm; bag filters or ESPs follow.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.