Worked example
Example: Hot flue gas, ash. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas viscosity | 2.5000e-05 Pa·s |
| Inlet width | 250.00 mm |
| Effective number of turns | 6.0000 - |
| Inlet velocity | 18.000 m/s |
| Particle density | 2,200.0 kg/m³ |
| Gas density | 0.80000 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cut diameter | 6.1394 µm |
Open this example in the calculator and change any input.
Formula
\(d_{50} = \sqrt{\frac{9\mu W}{2\pi N_e V_i(\rho_p - \rho_g)}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\mu\) | Gas viscosity | Pa·s |
| \(W\) | Inlet width | m |
| \(N_e\) | Effective number of turns | - |
| \(V_i\) | Inlet velocity | m/s |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_g\) | Gas density | kg/m³ |
| \(d_{50}\) | Cut diameter | m |
Method and standards
Lapple.
Where it is used
- Mechanical dust collectors on boilers.
- Pre-cleaners.
Common mistakes
- Diameter instead of inlet width.
- Cold gas viscosity for hot gas.
Assumptions and limits
- Conventional reverse-flow cyclone.
References
- Lapple (1951) cut diameter d₅₀ = [9μW/(2πN_eV_i(ρ_p − ρ_g))]^½
Questions and answers
250 mm inlet, 18 m/s, six turns, ash at 2200 kg/m³, hot gas?
d₅₀ about 6.1 µm.
How to lower d₅₀?
Narrower inlet, higher velocity or more turns, at more pressure drop.
Fine fly ash?
Cyclones miss most particles below about 5 µm; bag filters or ESPs follow.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.