Worked example
Example: 15 000 m2 at 150 m3/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effective migration velocity | 0.060000 m/s |
| Collecting plate area | 15,000 m² |
| Gas flow (actual) | 540,000 m³/h |
| Target efficiency | 99.800 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific collecting area A/Q | 100.00 m²/(m³/s) |
| Collection efficiency | 99.752 % |
| Area for the target | 15,537 m² |
Open this example in the calculator and change any input.
Formula
\(\eta = 1 - \exp\left(-\frac{wA}{\dot V}\right), \quad A_t = -\frac{\dot V}{w}\ln(1 - \eta_t)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(w\) | Effective migration velocity | m/s |
| \(A\) | Collecting plate area | m² |
| \(\dot V\) | Gas flow (actual) | m³/s |
| \(\eta_t\) | Target efficiency | - |
| \(SCA\) | Specific collecting area A/Q, in m² per m³/s (× 5.08 = ft² per 1000 acfm) | s/m |
| \(\eta\) | Collection efficiency | - |
| \(A_t\) | Area for the target | m² |
Method and standards
Deutsch–Anderson.
Where it is used
- ESP checks and upgrades.
- Boiler emission compliance.
Common mistakes
- Normal instead of actual flow.
- Test w applied to a different coal.
Assumptions and limits
- Uniform gas distribution.
- SCA is in m² per m³/s in every unit system; multiply by 5.08 for ft² per 1 000 acfm.
References
- Deutsch–Anderson η = 1 − exp(−wA/Q)
Questions and answers
15,000 m² at 150 m³/s with w 0.06 m/s?
99.75 %; 99.8 % needs 15,537 m².
Why does area grow fast at high efficiency?
Each extra 'nine' needs the same added SCA.
High-resistivity ash?
Lower w: low-sulphur coal ash often needs more area or flue gas conditioning.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.