FireCADCalc

CHP: Overall Efficiency and Primary Energy Saving

Overall efficiency of a combined heat and power plant and its primary energy saving against separate heat and power, using reference efficiencies (EU method).

Thermal power plantSugar mill and cogenerationPulp and paper

Inputs

Examples: Gas engine CHPBack-pressure steam turbine

From the harmonised reference values of your regulator for the fuel and year.

Results

High-efficiency cogeneration needs PES above the threshold your regulation sets.

Electrical efficiency35.000%
Heat efficiency45.000%
Overall efficiency80.000%
Primary energy saving14.286%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Gas engine CHP. The inputs, in the units selected above:

InputValue
Fuel input per year300,000 GJ
Electricity produced per year105,000 GJ
Useful heat per year135,000 GJ
Reference efficiency for separate power52.500 %
Reference efficiency for separate heat90.000 %

Applying the formula below gives:

ResultValue
Electrical efficiency35.000 %
Heat efficiency45.000 %
Overall efficiency80.000 %
Primary energy saving14.286 %

Open this example in the calculator and change any input.

Formula

\(PES = 1 - \frac{1}{\frac{\eta_H}{\eta_{ref,H}} + \frac{\eta_E}{\eta_{ref,E}}}\)

Variables

Symbol Meaning SI unit
\(F\) Fuel input per year J
\(E\) Electricity produced per year J
\(H\) Useful heat per year J
\(\eta_{ref,E}\) Reference efficiency for separate power -
\(\eta_{ref,H}\) Reference efficiency for separate heat -
\(\eta_E\) Electrical efficiency -
\(\eta_H\) Heat efficiency -
\(\eta_o\) Overall efficiency -
\(PES\) Primary energy saving -

Method and standards

EU method.

Where it is used

  • Cogeneration in sugar, paper and process plants.
  • Policy and incentive claims.

Common mistakes

  • Gross instead of net electricity.
  • Including heat that is not useful.

Assumptions and limits

  • Annual totals.
  • The regulatory calculation applies correction factors to η_ref,E (average climate, avoided grid losses) and puts all efficiencies on the net calorific value of the fuel; enter the corrected reference values and NCV-based energies, or the PES here may differ from the regulatory one.

References

  • PES = 1 − 1/(η_H/η_ref,H + η_E/η_ref,E) (EU Directive 2012/27/EU, Annex II)

Questions and answers

35 % electrical and 45 % heat efficiency?

PES about 14.3 % against references 52.5 % and 90 %.

Sugar mill cogeneration?

Back-pressure turbines give high heat efficiency and strong PES.

Reference values?

Your regulator's harmonised values for the fuel and year of build.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.