FireCADCalc

Biogas from Spent Wash by Biomethanation (COD Basis)

Methane and biogas from the COD removed in an anaerobic digester (0.35 Nm³ CH₄ per kg COD at 0 °C), and the energy in the methane.

Distillery and ethanol

Inputs

Examples: 110 t/d COD, 65 % removedSmaller digester

Results

COD used for sludge growth or reduced by sulphate makes no methane: use the COD actually converted.

Methane per kg COD removed0.35024m³/kg
Methane25,042Nm³/d
Biogas43,176Nm³/d
Energy in the methane10.376MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 110 t/d COD, 65 % removed. The inputs, in the units selected above:

InputValue
COD load to the digester110.00 t/d
COD removed (converted to methane)65.000 %
Methane in biogas (by volume)58.000 %
Methane net heating value35.800 MJ/Nm³

Applying the formula below gives:

ResultValue
Methane per kg COD removed0.35024 m³/kg
Methane25,042 Nm³/d
Biogas43,176 Nm³/d
Energy in the methane10.376 MW

Open this example in the calculator and change any input.

Formula

\(Y = \frac{V_m}{2 M_{O_2}} \approx 0.35\;\mathrm{Nm^3/kg}, \quad \dot V_{CH_4} = L_{COD} \eta_{COD} Y, \quad \dot V_b = \frac{\dot V_{CH_4}}{y_{CH_4}}\)

Variables

Symbol Meaning SI unit
\(L_{COD}\) COD load to the digester kg/s
\(\eta_{COD}\) COD removed (converted to methane) -
\(y_{CH_4}\) Methane in biogas (by volume) -
\(LHV\) Methane net heating value J/m³
\(Y\) Methane per kg COD removed m³/kg
\(\dot V_{CH_4}\) Methane Nm³/s
\(\dot V_b\) Biogas Nm³/s
\(\dot E\) Energy in the methane W

Method and standards

COD stoichiometry.

Where it is used

  • Digester design and biogas planning.
  • Carbon credit estimates.

Common mistakes

  • COD load used instead of COD removed.

Assumptions and limits

  • Ideal gas at 0 °C, 1 atm; dry gas. Digester gas is saturated with water vapour (about 5–6 % by volume at 35 °C), so the wet gas volume is larger.

References

  • COD equivalence of methane CH₄ + 2 O₂ → CO₂ + 2 H₂O: 0.350 Nm³ CH₄ per kg COD at 0 °C
  • 1 atm (IPCC 2006 Vol. 5 uses 0.25 kg CH₄/kg COD)

Questions and answers

Where does 0.35 come from?

One mol of methane needs two mol of oxygen (64 g of COD); one mol of gas is 22.4 L at 0 °C.

Why is actual yield lower?

Part of the COD becomes sludge and sulphate reduction makes H₂S instead.

At 35 °C?

The same gas occupies about 13 % more; this calculator reports normal cubic metres.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.