Worked example
Example: 110 t/d COD at 8 kg/m3 d. The inputs, in the units selected above:
| Input | Value |
|---|---|
| COD load | 110.00 t/d |
| Organic loading rate | 8.0000 kg/(m³·d) |
| Spent wash flow | 1,000.0 m³/d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Digester volume | 13,750 m³ |
| Hydraulic retention time | 13.750 d |
Open this example in the calculator and change any input.
Formula
\(V = \frac{L_{COD}}{OLR}, \quad HRT = \frac{V}{\dot V}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_{COD}\) | COD load | kg/s |
| \(OLR\) | Organic loading rate | kg/(m³·s) |
| \(\dot V\) | Spent wash flow | m³/s |
| \(V\) | Digester volume | m³ |
| \(HRT\) | Hydraulic retention time | s |
Method and standards
Definitions.
Where it is used
- Biomethanation plant design.
Common mistakes
- OLR on the gross instead of the working volume.
Assumptions and limits
- Steady load.
References
- V = COD load / OLR; HRT = V/Q
Questions and answers
What OLR?
Several kg COD/m³·d for high-rate reactors on spent wash; less for lagoons.
HRT or OLR?
Strong wastes are limited by OLR; dilute ones by HRT.
Temperature?
Mesophilic digesters run near 35–38 °C; spent wash leaves the still hot and is cooled.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.