Worked example
Example: 9 % wash, live steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wash strength | 9.0000 % |
| Live steam injected per litre of AA | 2.0000 kg/L |
| Plant capacity (absolute alcohol) | 100.00 kL/d |
| Spent wash density | 1,040.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Spent wash per litre of AA | 12.034 |
| Spent wash per day | 1,203.4 m³/d |
Open this example in the calculator and change any input.
Formula
\(v_{sw} = \frac{1}{s_v} - 1 + \frac{s_s}{\rho_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(s_v\) | Wash strength | - |
| \(s_s\) | Live steam injected per litre of AA | kg/m³ |
| \(\dot V_e\) | Plant capacity (absolute alcohol) | m³/s |
| \(\rho_w\) | Spent wash density | kg/m³ |
| \(v_{sw}\) | Spent wash per litre of AA | - |
| \(\dot V_{sw}\) | Spent wash per day | m³/s |
Method and standards
Volume balance.
Where it is used
- ZLD planning.
- Pollution control consent applications.
Common mistakes
- Bulk litres used.
Assumptions and limits
- Volumes additive.
- Only the absolute alcohol is taken out of the wash: water leaving with the overhead (low wines) and the lees stream are not separated, and condensed steam is counted at the spent wash density. The result is an estimate; measure the flow.
References
- Volume balance: wash per litre of AA = 1/s_v; less the alcohol; plus condensed live steam
Questions and answers
How to cut spent wash?
Higher wash strength, reboilers instead of live steam, and recycle of spent wash to dilution.
Why does live steam add spent wash?
Injected steam condenses into the bottoms.
Is the estimate exact?
No: densities, contraction and recycle shift it; measure the flow.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.