Worked example
Example: 650 m3/d at 85 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Process condensate | 650.00 m³/d |
| Recovery (permeate / feed) | 85.000 % |
| Feed COD | 1,500.0 mg/L |
| COD rejection by the membranes | 95.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Permeate | 552.50 m³/d |
| Reject | 97.500 m³/d |
| Permeate COD | 75.000 mg/L |
| Reject COD | 9,575.0 mg/L |
Open this example in the calculator and change any input.
Formula
\(\dot V_p = \dot V R, \quad c_p = c_f (1 - \rho_r), \quad c_r = \frac{\dot V c_f - \dot V_p c_p}{\dot V - \dot V_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Process condensate | m³/s |
| \(R\) | Recovery (permeate / feed) | - |
| \(c_f\) | Feed COD | kg/m³ |
| \(\rho_r\) | COD rejection by the membranes | - |
| \(\dot V_p\) | Permeate | m³/s |
| \(\dot V_r\) | Reject | m³/s |
| \(c_p\) | Permeate COD | kg/m³ |
| \(c_r\) | Reject COD | kg/m³ |
Method and standards
Mass balance.
Where it is used
- CPU sizing.
- ZLD balance.
Common mistakes
- Rejection applied to the reject.
Assumptions and limits
- Single stage.
- The rejection is applied to the feed COD. In a real RO stage the permeate follows the mean feed-side concentration, which rises with recovery, so at high recovery the permeate COD here is understated and the reject COD overstated.
References
- Flow and solute balance across a membrane stage with a rejection
Questions and answers
Why polish condensate?
Evaporator condensate carries volatile organics; polished, it replaces fresh water.
Recovery limit?
Fouling and the reject's strength; 80–90 % is common.
Rejection?
The share of COD the membrane holds back; volatile acids pass more easily.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.