FireCADCalc

Slop-Fired Boiler: Steam from Concentrate and Support Fuel

Steam raised by burning concentrated spent wash and the support fuel (coal or bagasse) to make up a steam demand, with IF97 steam and feedwater enthalpies.

Sugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 25 t/h on slop + coalMostly coal

Results

Combustion stability and ash behaviour set the minimum support-fuel share: follow the boiler maker's limit.

Heat per kg of steam2,760.2kJ/kg
Steam from concentrate15.307t/h
Support fuel1.5538t/h
Concentrate share of heat input66.578%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 25 t/h on slop + coal. The inputs, in the units selected above:

InputValue
Steam demand25.000 t/h
Steam pressure (absolute)46.000 bar
Steam temperature400.00 °C
Feedwater temperature105.00 °C
Concentrate fired10.000 t/h
Concentrate NCV (as fired)6,500.0 kJ/kg
Efficiency on concentrate (net)65.000 %
Support fuel NCV21,000 kJ/kg
Efficiency on support fuel (net)82.000 %

Applying the formula below gives:

ResultValue
Heat per kg of steam2,760.2 kJ/kg
Steam from concentrate15.307 t/h
Support fuel1.5538 t/h
Concentrate share of heat input66.578 %

Open this example in the calculator and change any input.

Formula

\(\dot m_{s,c} = \frac{\dot m_c NCV_c \eta_c}{\Delta h}, \quad \dot m_f = \frac{(\dot m_s - \dot m_{s,c})\Delta h}{NCV_f \eta_f}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) Steam demand kg/s
\(p\) Steam pressure (absolute) Pa
\(T_s\) Steam temperature K
\(T_{fw}\) Feedwater temperature K
\(\dot m_c\) Concentrate fired kg/s
\(NCV_c\) Concentrate NCV (as fired) J/kg
\(\eta_c\) Efficiency on concentrate (net) -
\(NCV_f\) Support fuel NCV J/kg
\(\eta_f\) Efficiency on support fuel (net) -
\(\Delta h\) Heat per kg of steam J/kg
\(\dot m_{s,c}\) Steam from concentrate kg/s
\(\dot m_f\) Support fuel kg/s
\(s_c\) Concentrate share of heat input -

Method and standards

Energy balance.

Where it is used

  • Incineration boiler sizing and operation.
  • Distillery fuel budgets.

Common mistakes

  • Gross and net efficiencies mixed.

Assumptions and limits

  • Steady firing.
  • Feedwater must be liquid at the steam pressure (below its saturation temperature).

References

  • Energy balance with IAPWS-IF97 steam and feedwater enthalpies; concentrate NCV from analysis (see slop-concentrate-net-value)

Questions and answers

Why support fuel?

Concentrate at 55–60 % solids burns weakly; coal or bagasse keeps the furnace hot and stable.

Efficiency on concentrate?

Lower than on coal: water in the concentrate leaves as vapour and the ash fouls.

Steam use?

Usually the distillery's own process steam, sometimes through a back-pressure turbine.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.