FireCADCalc

MVR Evaporator: Compressor Power from Temperature Lift

Pressure ratio and power of a mechanical vapour recompression (MVR) compressor from the vapour flow, its saturation temperature, the lift and the efficiency (IF97).

Distillery and ethanolFood, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: 90 °C, 10 K lift60 °C, 15 K lift

Results

The lift must cover the boiling-point elevation plus the heat-transfer ΔT; high-solids liquors need more lift.

Shaft power only: add mechanical, gearbox and motor losses for the electrical demand.

Suction pressure70.182kPa
Discharge pressure101.42kPa
Pressure ratio1.4451
Compressor shaft power226.99kW
Energy per tonne of vapour22.699kWh/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 90 °C, 10 K lift. The inputs, in the units selected above:

InputValue
Vapour compressed10.000 t/h
Saturation temperature of the vapour90.000 °C
Saturation temperature lift10.000 K
Isentropic efficiency78.000 %

Applying the formula below gives:

ResultValue
Suction pressure70.182 kPa
Discharge pressure101.42 kPa
Pressure ratio1.4451
Compressor shaft power226.99 kW
Energy per tonne of vapour22.699 kWh/t

Open this example in the calculator and change any input.

Formula

\(p_i = p_{sat}(T_i), \quad w = \frac{h(p_2, s_1) - h_1}{\eta_s}, \quad P = \dot m_v w\)

Variables

Symbol Meaning SI unit
\(\dot m_v\) Vapour compressed kg/s
\(T_1\) Saturation temperature of the vapour K
\(\Delta T\) Saturation temperature lift K
\(\eta_s\) Isentropic efficiency -
\(p_1\) Suction pressure Pa
\(p_2\) Discharge pressure Pa
\(p_2/p_1\) Pressure ratio -
\(P\) Compressor shaft power W
\(e\) Energy per tonne of vapour J/kg

Method and standards

IF97 isentropic compression.

Where it is used

  • MVR evaporator sizing.
  • ZLD energy studies.

Common mistakes

  • Lift taken as pressure ratio.
  • BPE not added to the lift.

Assumptions and limits

  • Saturated suction vapour at T₁. Vapour from a boiling liquor is in fact superheated by the boiling-point elevation; the lift entered must include that elevation.
  • Shaft power from the isentropic efficiency only; mechanical, gearbox and motor losses are extra.

References

  • Isentropic compression of saturated steam with IAPWS-IF97 (saturation pressures, entropy and enthalpy)

Questions and answers

Why is MVR cheap to run?

It recycles latent heat: the compressor adds only the energy of the lift.

Typical energy?

Some 15–40 kWh per tonne of water for lifts of 8–15 K.

Desuperheating?

Compressed vapour is superheated; it is often desaturated with a water spray.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.