Worked example
Example: Circular clarifier 20 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 400.00 m³/h |
| Tank shape | Circular |
| Length (rectangular) | 30.000 m |
| Width (rectangular) | 8.0000 m |
| Diameter (circular) | 20.000 m |
| Side water depth | 3.5000 m |
| Total outlet weir length (0: end width of a rectangular tank, perimeter of a circular one) | 0 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Surface area | 314.16 m² |
| Volume | 1,099.6 m³ |
| Detention time | 2.7489 h |
| Surface overflow rate | 1.2732 m/h |
| Weir loading | 152.79 m³/(d·m) |
Open this example in the calculator and change any input.
Formula
\(t_d = \frac{V}{\dot V}, \quad v_o = \frac{\dot V}{A}, \quad q_w = \frac{\dot V}{L_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Flow | m³/s |
| \(\text{shape}\) | Tank shape | - |
| \(L\) | Length (rectangular) | m |
| \(W\) | Width (rectangular) | m |
| \(D\) | Diameter (circular) | m |
| \(H\) | Side water depth | m |
| \(L_w\) | Total outlet weir length (0: end width of a rectangular tank, perimeter of a circular one) | m |
| \(A\) | Surface area | m² |
| \(V\) | Volume | m³ |
| \(t_d\) | Detention time | s |
| \(v_o\) | Surface overflow rate | m/s |
| \(q_w\) | Weir loading | m³/(s·m) |
Method and standards
Definitions.
Where it is used
- Clarifiers for raw water and effluent.
- Ash pond and settling pit checks.
Common mistakes
- Using total depth with sludge zone.
- Peak vs average flow.
Assumptions and limits
- Uniform flow.
- With zero flow the detention time is not defined and is not shown.
References
- Detention time V/Q
- surface overflow rate Q/A
- weir loading Q/L_w (Metcalf & Eddy; water treatment texts)
Questions and answers
400 m³/h in a 20 m circular tank, 3.5 m deep?
Detention 2.7 h, overflow 1.27 m/h, weir loading 153 m³/(d·m).
Which limits apply?
Your design standard's, by tank type and solids.
Short-circuiting?
Real detention is shorter than V/Q; baffles help.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.