Worked example
Example: Pumping station 120 m3/min, 50 ppmv, 25 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air flow | 120.00 m³/min |
| H₂S in the air (ppmv) | 50.000 - |
| Air temperature | 25.000 °C |
| Air pressure | 1.0000 atm |
| Air density | 1.2040 kg/m³ |
| Liquid-to-gas mass ratio | 2.0000 - |
| Caustic solution density | 1,520.0 kg/m³ |
| NaOH in the solution | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| H₂S concentration | 69.649 mg/m³ |
| H₂S to treat | 12.035 kg/d |
| Sodium hypochlorite (8.74 kg/kg) | 105.15 kg/d |
| Caustic (2.35 kg/kg) | 28.252 kg/d |
| Caustic solution volume | 37.174 L/d |
| Scrubbing water | 0.28896 m³/min |
Open this example in the calculator and change any input.
Formula
\(C_{H_2S} = y\frac{pM_{H_2S}}{RT}, \quad M_{NaOCl} = \frac{4M_{NaOCl}}{M_{H_2S}}M_{H_2S}, \quad M_{NaOH} = \frac{2M_{NaOH}}{M_{H_2S}}M_{H_2S}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_a\) | Air flow | m³/s |
| \(y\) | H₂S in the air (ppmv) | - |
| \(T\) | Air temperature | K |
| \(p\) | Air pressure | Pa |
| \(\rho_a\) | Air density | kg/m³ |
| \(L/G\) | Liquid-to-gas mass ratio | - |
| \(\rho_s\) | Caustic solution density | kg/m³ |
| \(w\) | NaOH in the solution | - |
| \(C_{H_2S}\) | H₂S concentration | kg/m³ |
| \(M_{H_2S}\) | H₂S to treat | kg/s |
| \(M_{NaOCl}\) | Sodium hypochlorite (8.74 kg/kg) | kg/s |
| \(M_{NaOH}\) | Caustic (2.35 kg/kg) | kg/s |
| \(V_{NaOH}\) | Caustic solution volume | m³/s |
| \(Q_w\) | Scrubbing water | m³/s |
Method and standards
Stoichiometric chemical scrubber requirements.
Where it is used
- Odour control at pumping stations and headworks.
- Chemical storage sizing.
Common mistakes
- Using ppm by mass.
- Ignoring caustic make-up.
Assumptions and limits
- Complete oxidation to sulphate; real consumption is higher.
Questions and answers
Is the caustic always needed?
It replaces the alkalinity the reaction consumes; if the scrubbing water has enough alkalinity, less or none is added.
What do the defaults represent?
An illustrative case: Pumping station 120 m3/min, 50 ppmv, 25 C. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 16-3, eq. 16-3, Table 16-9 and Example 16-1