Worked example
Example: Stripping factor 2, same water. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water flow | 4,000.0 m³/d |
| Inlet ammonia | 40.000 mg/L |
| Outlet ammonia | 1.0000 mg/L |
| Henry's constant (atm) | 0.75000 - |
| Total pressure | 1.0000 atm |
| Stripping factor | 2.0000 - |
| Overall transfer coefficient | 0.012500 1/s |
| Ordinate from the pressure-drop chart | 0.30000 - |
| Packing factor | 20.000 - |
| Air density | 1.2040 kg/m³ |
| Water density | 998.20 kg/m³ |
| Water viscosity | 1.0020 cP |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air-to-water ratio by volume | 3,555.3 m³/m³ |
| Abscissa (L'/G')(ρ_G/ρ_L)^½ | 0.008104 |
| Gas loading | 4.2429 kg/(m²·s) |
| Liquid loading | 0.98942 kg/(m²·s) |
| Tower diameter | 7.7117 m |
| Height of a transfer unit | 0.079296 m |
| Number of transfer units | 6.0408 |
| Packing height | 0.47902 m |
Open this example in the calculator and change any input.
Formula
\(\frac{G}{L} = \frac{SP_T}{H}, \quad G' = \left[\frac{Y\rho_G(\rho_L - \rho_G)}{C_f\mu_L^{0.1}}\right]^{1/2}, \quad A = \frac{Q\rho_L}{L'}\)
\(HTU = \frac{Q}{K_LaA}, \quad NTU = \frac{S}{S - 1}\ln\frac{(C_o/C_e)(S - 1) + 1}{S}, \quad Z = HTU\cdot NTU\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Water flow | m³/s |
| \(C_o\) | Inlet ammonia | kg/m³ |
| \(C_e\) | Outlet ammonia | kg/m³ |
| \(H\) | Henry's constant (atm) | - |
| \(P_T\) | Total pressure | Pa |
| \(S\) | Stripping factor | - |
| \(K_La\) | Overall transfer coefficient | 1/s |
| \(Y\) | Ordinate from the pressure-drop chart | - |
| \(C_f\) | Packing factor | - |
| \(\rho_G\) | Air density | kg/m³ |
| \(\rho_L\) | Water density | kg/m³ |
| \(\mu_L\) | Water viscosity | Pa·s |
| \(G/L\) | Air-to-water ratio by volume | m³/m³ |
| \(X\) | Abscissa (L'/G')(ρ_G/ρ_L)^½ | - |
| \(G'\) | Gas loading | kg/(m²·s) |
| \(L'\) | Liquid loading | kg/(m²·s) |
| \(D\) | Tower diameter | m |
| \(HTU\) | Height of a transfer unit | m |
| \(NTU\) | Number of transfer units | - |
| \(Z\) | Packing height | m |
Method and standards
Packed tower stripping design (HTU-NTU method).
Where it is used
- Ammonia and VOC stripping.
- Sizing packed towers from pilot K_La.
Common mistakes
- Using the area from the gas loading.
- Taking Henry's constant at the wrong temperature.
Assumptions and limits
- Dilute, isothermal; K_La from pilot data or a correlation.
Questions and answers
Why is ammonia hard to strip?
Its Henry's constant is low (0.75 atm at 20 °C) and only free NH₃ strips, so the pH must be raised to about 11 and very large air flows are needed.
What do the defaults represent?
An illustrative case: Stripping factor 2, same water. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 11-10, eqs. 11-95 to 11-103 and Example 11-16