Worked example
Example: Illustrative 50 m3/day RO reject. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effluent to evaporate per day | 50.000 m³ |
| Pan evaporation (mm per day) | 6.0000 - |
| Pan coefficient | 70.000 % |
| Average rainfall (mm per day) | 2.0000 - |
| Salinity reduction factor of evaporation | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Net evaporation (mm per day) | 1.3600 |
| Pond surface area | 36,765 m² |
| Pond area | 3.6765 ha |
Open this example in the calculator and change any input.
Formula
\(E_n = k_p E_p f_s - R, \quad A = \frac{Q}{E_n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Effluent to evaporate per day | m³ |
| \(E_p\) | Pan evaporation (mm per day) | - |
| \(k_p\) | Pan coefficient | - |
| \(R\) | Average rainfall (mm per day) | - |
| \(f_s\) | Salinity reduction factor of evaporation | - |
| \(E_n\) | Net evaporation (mm per day) | - |
| \(A\) | Pond surface area | m² |
| \(A_{ha}\) | Pond area | m² |
Method and standards
Evaporation pond.
Where it is used
- ZLD and RO reject disposal.
- Mining and industrial effluent ponds.
Common mistakes
- Using annual average evaporation.
- Ignoring rainfall on the pond.
Assumptions and limits
- Average rates over the design period.
References
- Water balance of evaporation ponds with pan coefficient
Questions and answers
How big a pond for 50 m³/day?
With 6 mm/day pan evaporation, coefficient 0.7, salinity factor 0.8 and 2 mm/day rain, about 3.7 ha.
Why use the worst month?
Evaporation can fall below rainfall in the monsoon; the pond must store the excess.
What do the defaults represent?
An illustrative 50 m³/day of RO reject, 6 mm/day pan evaporation, 2 mm/day rain.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.