Worked example
Example: Illustrative 150-person reed bed. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Daily flow | 20.000 m³/d |
| Inlet BOD | 150.00 mg/L |
| Outlet BOD wanted | 20.000 mg/L |
| Area rate constant | 0.10000 m/d |
| Population served (0 = skip) | 150.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bed area | 402.98 m² |
| Area per person | 2.6865 m² |
| Hydraulic loading | 49.630 mm/d |
Open this example in the calculator and change any input.
Formula
\(A = \frac{Q\left(\ln C_i - \ln C_o\right)}{K_{BOD}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Daily flow | m³/s |
| \(C_i\) | Inlet BOD | kg/m³ |
| \(C_o\) | Outlet BOD wanted | kg/m³ |
| \(K_{BOD}\) | Area rate constant | m/s |
| \(N\) | Population served (0 = skip) | - |
| \(A\) | Bed area | m² |
| \(A/N\) | Area per person | m² |
| \(q_h\) | Hydraulic loading | m/s |
Method and standards
Constructed wetland.
Where it is used
- Small communities, resorts and schools.
- Polishing STP effluent.
Common mistakes
- Using raw sewage BOD without pre-treatment.
- Using one K value for all climates.
Assumptions and limits
- Horizontal subsurface flow; first-order BOD removal.
References
- Kickuth horizontal-flow constructed wetland sizing equation
Questions and answers
How much reed bed for 20 m³/day from 150 to 20 mg/L BOD?
About 400 m², or 2.7 m² per person for 150 people.
Why pre-treat?
Suspended solids clog the gravel and stop subsurface flow.
What do the defaults represent?
An illustrative 20 m³/day of settled sewage from 150 people, BOD 150 mg/L to 20 mg/L, K = 0.1 m/day.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.