Worked example
Example: Primary sludge only, 120 kg/m2.d. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Primary sludge flow | 150.00 m³/d |
| Primary sludge specific gravity | 1.0200 - |
| Primary sludge solids | 4.0000 % |
| Waste activated sludge flow | 0 m³/d |
| WAS specific gravity | 1.0000 - |
| WAS solids | 0 % |
| Combined sludge specific gravity | 1.0200 - |
| Solids loading | 120.00 kg/(m²·d) |
| Number of thickeners | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Primary dry solids | 6,120.0 kg/d |
| WAS dry solids | 0 kg/d |
| Combined dry solids | 6,120.0 kg/d |
| Combined flow | 150.00 m³/d |
| Combined solids | 4.0000 % |
| Total area | 51.000 m² |
| Hydraulic loading | 2.9412 m/d |
| Diameter of each thickener | 8.0582 m |
Open this example in the calculator and change any input.
Formula
\(M_i = Q_i\,SG_i\,\rho_w\,P_i, \quad P = \frac{M_1 + M_2}{(Q_1 + Q_2)SG_m\rho_w}, \quad A = \frac{M}{SL}, \quad D = \sqrt{\frac{4A}{n\pi}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_1\) | Primary sludge flow | m³/s |
| \(SG_1\) | Primary sludge specific gravity | - |
| \(P_1\) | Primary sludge solids | - |
| \(Q_2\) | Waste activated sludge flow | m³/s |
| \(SG_2\) | WAS specific gravity | - |
| \(P_2\) | WAS solids | - |
| \(SG_m\) | Combined sludge specific gravity | - |
| \(SL\) | Solids loading | kg/(m²·s) |
| \(n\) | Number of thickeners | - |
| \(M_1\) | Primary dry solids | kg/s |
| \(M_2\) | WAS dry solids | kg/s |
| \(M\) | Combined dry solids | kg/s |
| \(Q\) | Combined flow | m³/s |
| \(P\) | Combined solids | - |
| \(A\) | Total area | m² |
| \(HL\) | Hydraulic loading | m/s |
| \(D\) | Diameter of each thickener | m |
Method and standards
Solids-loading design of gravity thickeners.
Where it is used
- Sludge thickener sizing.
- Checking thickener loading in operation.
Common mistakes
- Designing on average instead of peak solids.
- Mixing percent and fraction.
Assumptions and limits
- Typical-value design; settling tests are better.
Questions and answers
Why check the hydraulic loading?
A gravity thickener sized on solids alone may see so little flow that sludge goes septic; dilution water or effluent recycle raises the overflow.
Should WAS go to a gravity thickener?
Waste activated sludge thickens poorly by gravity; flotation, centrifuges or gravity belts are often used for it, with the primary sludge thickened separately.
What do the defaults represent?
An illustrative case: Primary sludge only, 120 kg/m2.d. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 13-6, Table 13-19 and Example 13-4