FireCADCalc

Granular Filter Backwash: Expanded Bed Depth

Expanded depth of a stratified sand or anthracite bed at a backwash rate, from the size fractions, settling velocities and the expanded porosity (v/vs)^0.22.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Same bed in winter water at 5 CAnthracite cap SG 1.6, 0.5 m/min, 15 C

Accepted: 0.006 to 3 m/min
Accepted: 0.1 to 3 m
Accepted: 30 to 60 %
Accepted: 1.1 to 5
Accepted: 1 to 40 °C
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %
Accepted: 0.01 to 5 mm
Accepted: 0 to 100 %

Results

Fractions are normalised to their total.

The coarsest fraction is fluidised: the whole bed expands.

Expanded bed depth1.4858m
Bed expansion65.090%
Expanded porosity of the coarsest fraction0.49906
Settling velocity of the coarsest fraction0.29439m/s
Settling velocity of the finest fraction0.046469m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same bed in winter water at 5 C. The inputs, in the units selected above:

InputValue
Backwash rate0.75000 m/min
Bed depth0.90000 m
Bed porosity (fixed)40.000 %
Media specific gravity2.6500 -
Water temperature5.0000 °C
Size of fraction 12.1800 mm
Mass fraction 11.0000 %
Size of fraction 21.8300 mm
Mass fraction 23.0000 %
Size of fraction 31.3000 mm
Mass fraction 316.000 %
Size of fraction 40.92000 mm
Mass fraction 416.000 %
Size of fraction 50.71000 mm
Mass fraction 530.000 %
Size of fraction 60.50000 mm
Mass fraction 622.000 %
Size of fraction 70.35000 mm
Mass fraction 712.000 %

Applying the formula below gives:

ResultValue
Expanded bed depth1.4858 m
Bed expansion65.090 %
Expanded porosity of the coarsest fraction0.49906
Settling velocity of the coarsest fraction0.29439 m/s
Settling velocity of the finest fraction0.046469 m/s

Open this example in the calculator and change any input.

Formula

\(\frac{L_e}{L} = (1 - \alpha)\sum\frac{p_i}{1 - \alpha_{e,i}}, \quad \alpha_{e,i} = \left(\frac{v}{v_{s,i}}\right)^{0.22}, \quad C_d = \frac{24}{Re} + \frac{3}{\sqrt{Re}} + 0.34\)

Variables

Symbol Meaning SI unit
\(v\) Backwash rate m/s
\(L\) Bed depth m
\(\alpha\) Bed porosity (fixed) -
\(s\) Media specific gravity -
\(T\) Water temperature K
\(d_1\) Size of fraction 1 m
\(p_1\) Mass fraction 1 -
\(d_2\) Size of fraction 2 m
\(p_2\) Mass fraction 2 -
\(d_3\) Size of fraction 3 m
\(p_3\) Mass fraction 3 -
\(d_4\) Size of fraction 4 m
\(p_4\) Mass fraction 4 -
\(d_5\) Size of fraction 5 m
\(p_5\) Mass fraction 5 -
\(d_6\) Size of fraction 6 m
\(p_6\) Mass fraction 6 -
\(d_7\) Size of fraction 7 m
\(p_7\) Mass fraction 7 -
\(L_e\) Expanded bed depth m
\((L_e - L)/L\) Bed expansion -
\(\alpha_{e,1}\) Expanded porosity of the coarsest fraction -
\(v_{s,1}\) Settling velocity of the coarsest fraction m/s
\(v_{s,7}\) Settling velocity of the finest fraction m/s

Method and standards

Fair and Geyer expansion with the Richardson-Zaki type porosity relation.

Where it is used

  • Setting backwash rates and trough heights.
  • Checking seasonal temperature effects on backwash.

Common mistakes

  • Using the effective size for the whole bed.
  • Ignoring temperature: cold water expands the bed more.

Assumptions and limits

  • Spherical-particle drag law; sieve geometric mean sizes.

Questions and answers

How much expansion is wanted?

Typically 30-50 %; the bottom of the wash troughs is set 50-150 mm above the expanded bed.

Why must the coarsest fraction expand?

If its expanded porosity stays below the fixed-bed porosity, the coarse grains at the bottom are not fluidised and the bed will not be cleaned throughout.

What do the defaults represent?

An illustrative case: Same bed in winter water at 5 C. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 11-4, eq. 11-19 and Example 11-2; drag law eq. 5-10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.