FireCADCalc

Pressure Drop Through a Packed Bed (Ergun Equation)

Pressure drop of a fluid flowing through a packed bed of particles from bed depth, particle size, voidage and superficial velocity, by the Ergun equation.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Air through 1 m of 5 mm spheres, ε 0.4, 0.5 m/sWater through sand filter: 0.8 m, 0.8 mm, ε 0.42, φ 0.8, 5 m/hCatalyst 3 m of 3 mm, ε 0.36, gas 5 kg/m³ at 0.3 m/s

Results

Pressure gradient in Pa per metre. Voidage dominates: a few per cent change in ε moves the result a lot.

Pressure gradient1,288.1Pa/m
Pressure drop over the bed1.2881kPa
Viscous term0.30375kPa
Inertial term0.98437kPa
Particle Reynolds number277.78

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air through 1 m of 5 mm spheres, ε 0.4, 0.5 m/s. The inputs, in the units selected above:

InputValue
Bed depth1.0000 m
Particle diameter (equivalent sphere)5.0000 mm
Bed voidage40.000 %
Sphericity1.0000 -
Superficial velocity (flow / bed area)0.50000 m/s
Fluid density1.2000 kg/m³
Fluid viscosity1.8000e-05 Pa·s

Applying the formula below gives:

ResultValue
Pressure gradient1,288.1 Pa/m
Pressure drop over the bed1.2881 kPa
Viscous term0.30375 kPa
Inertial term0.98437 kPa
Particle Reynolds number277.78

Open this example in the calculator and change any input.

Formula

\(\frac{\Delta p}{L} = 150\, \frac{\mu (1 - \varepsilon)^2 v_s}{\varepsilon^3 (\phi_s d_p)^2} + 1.75\, \frac{\rho (1 - \varepsilon) v_s^2}{\varepsilon^3 \phi_s d_p}\)

Variables

Symbol Meaning SI unit
\(L\) Bed depth m
\(d_p\) Particle diameter (equivalent sphere) m
\(\varepsilon\) Bed voidage -
\(\phi_s\) Sphericity -
\(v_s\) Superficial velocity (flow / bed area) m/s
\(\rho\) Fluid density kg/m³
\(\mu\) Fluid viscosity Pa·s
\(\Delta p/L\) Pressure gradient, in Pa/m Pa/m
\(\Delta p\) Pressure drop over the bed Pa
\(\Delta p_v\) Viscous term Pa
\(\Delta p_i\) Inertial term Pa
\(Re_p\) Particle Reynolds number -

Method and standards

Ergun's correlation.

Where it is used

  • Filters, adsorbers, catalyst beds.
  • Fluidised bed design (pressure at minimum fluidisation).

Common mistakes

  • Interstitial instead of superficial velocity.
  • Guessed voidage.

Assumptions and limits

  • Randomly packed bed.

References

  • S. Ergun
  • Fluid flow through packed columns
  • Chem. Eng. Prog. 48 (1952) 89

Questions and answers

Why two terms?

Viscous losses dominate at low Reynolds number, inertial losses at high.

How sensitive is it to voidage?

Very: (1 − ε)²/ε³ means 0.35 instead of 0.40 raises the viscous term by about 75 %.

What velocity?

Superficial: flow divided by the empty bed area.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.