Worked example
Example: 300 kPa, water up 12 m, 4 m loss. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure at point 1 | 300.00 kPa |
| Velocity at point 1 | 1.5000 m/s |
| Elevation of point 1 | 0 m |
| Velocity at point 2 | 3.0000 m/s |
| Elevation of point 2 | 12.000 m |
| Head loss between the points | 4.0000 m |
| Fluid density | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure at point 2 | 140.04 kPa |
| Total head at point 1 | 30.768 m |
| Total head at point 2 | 26.768 m |
Open this example in the calculator and change any input.
Formula
\(\frac{p_1}{\rho g} + \frac{v_1^2}{2g} + z_1 = \frac{p_2}{\rho g} + \frac{v_2^2}{2g} + z_2 + h_L\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Pressure at point 1 | Pa |
| \(v_1\) | Velocity at point 1 | m/s |
| \(z_1\) | Elevation of point 1 | m |
| \(v_2\) | Velocity at point 2 | m/s |
| \(z_2\) | Elevation of point 2 | m |
| \(h_L\) | Head loss between the points | m |
| \(\rho\) | Fluid density | kg/m³ |
| \(p_2\) | Pressure at point 2 | Pa |
| \(H_1\) | Total head at point 1 | m |
| \(H_2\) | Total head at point 2 | m |
Method and standards
Energy conservation along a streamline.
Where it is used
- Pipe pressure profiles.
- Fluid mechanics examinations.
Common mistakes
- Mixing gauge and absolute.
- Forgetting velocity head changes.
Assumptions and limits
- Incompressible, steady.
- A negative p₂ is flagged: impossible on an absolute basis, and on a gauge basis the absolute pressure must stay above the vapour pressure.
References
- Steady-flow energy equation for incompressible flow (Textbook fluid mechanics (White, Fluid Mechanics))
Questions and answers
300 kPa at ground level, water rising 12 m with 4 m of losses?
140 kPa at the top.
Gauge or absolute?
Either, as long as both points use the same.
When does Bernoulli fail?
For gases with large pressure changes, where density varies.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.