FireCADCalc

Power-Law (Non-Newtonian) Fluid Pressure Drop in a Pipe

Pressure drop of a power-law fluid in a pipe: Metzner–Reed Reynolds number, laminar f = 16/Re, and the Wilson–Thomas turbulent friction factor (Perry's sec. 6).

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Shear-thinning slurry, laminarThin polymer solution, turbulent

Always in Pa·sⁿ: 1 lbf·sⁿ/ft² = 47.880 Pa·sⁿ; 1 dyn·sⁿ/cm² (poise-type) = 0.1 Pa·sⁿ.

Results

Smooth pipe; for time-dependent or viscoelastic fluids the transition may move to higher Re.

Generalised consistency K' (Pa·sⁿ)5.5902
Metzner–Reed Reynolds number285.38
Fanning friction factor0.056066
Wall shear stress69.382Pa
Pressure drop356.26kPa
Regime (0 laminar, 1 turbulent)0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Shear-thinning slurry, laminar. The inputs, in the units selected above:

InputValue
Consistency index K (Pa·sⁿ)5.0000 -
Flow behaviour index n0.50000 -
Density1,100.0 kg/m³
Pipe inside diameter77.900 mm
Mean velocity1.5000 m/s
Pipe length100.00 m

Applying the formula below gives:

ResultValue
Generalised consistency K' (Pa·sⁿ)5.5902
Metzner–Reed Reynolds number285.38
Fanning friction factor0.056066
Wall shear stress69.382 Pa
Pressure drop356.26 kPa
Regime (0 laminar, 1 turbulent)0

Open this example in the calculator and change any input.

Formula

\(Re_{MR} = \frac{D^nV^{2-n}\rho}{K'8^{n-1}}, \quad K' = K\left(\frac{1 + 3n}{4n}\right)^n, \quad f = \frac{16}{Re_{MR}}\ \text{(laminar)}\)

\(\frac{1}{\sqrt f} = \frac{1}{\sqrt{f_N}} + 8.2\frac{1 - n}{1 + n} + 1.77\ln\frac{1 + n}{2}, \quad \Delta p = 4f\frac{L}{D}\frac{\rho V^2}{2}\)

Variables

Symbol Meaning SI unit
\(K\) Consistency index K (Pa·sⁿ) -
\(n\) Flow behaviour index n -
\(\rho\) Density kg/m³
\(D\) Pipe inside diameter m
\(V\) Mean velocity m/s
\(L\) Pipe length m
\(K'\) Generalised consistency K' (Pa·sⁿ) -
\(Re_{MR}\) Metzner–Reed Reynolds number -
\(f\) Fanning friction factor -
\(\tau_w\) Wall shear stress Pa
\(\Delta p\) Pressure drop Pa
\(\text{regime}\) Regime (0 laminar, 1 turbulent) -

Method and standards

Metzner–Reed generalised Reynolds number; Wilson–Thomas turbulent correction; f_N for a Newtonian fluid at the wall viscosity.

Where it is used

  • Polymer, food and slurry lines.
  • Molasses and massecuite transfer.

Common mistakes

  • Using an apparent viscosity at the wrong shear rate.
  • Applying it to Bingham plastics.

Assumptions and limits

  • Time-independent power-law fluids; smooth pipes.
  • K is entered in Pa·sⁿ in every unit system.
  • Laminar–turbulent switch at a fixed Re_MR of 2 100; the critical Reynolds number of power-law fluids depends on n (it rises for strongly shear-thinning fluids), so results near the switch are uncertain.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 6
  • Eqs. (6-64) to (6-69) (Metzner and Reed; Wilson and Thomas)
  • Smooth-pipe Newtonian friction 1/√f = 4 log(Re√f) − 0.4 (Prandtl–Kármán)

Questions and answers

What is a power-law fluid?

One whose shear stress is K·γ̇ⁿ: n < 1 is shear-thinning (polymer solutions, many slurries, molasses at high shear), n > 1 shear-thickening.

When is the flow laminar?

Below a Metzner–Reed Reynolds number of about 2,100; most viscous non-Newtonian process lines are laminar.

Where do K and n come from?

From a viscometer: the slope and intercept of log shear stress against log shear rate.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.