FireCADCalc

Siphon Flow Rate and Maximum Height

Flow through a siphon from the level difference, pipe size, length and losses, the pressure at the crest and the highest crest before the liquid boils off.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 3 m level difference, 2 m crest, 50 mm, K 6Warm water 60 °C: 2 m, 4 m crestLong hose: 1 m, 1 m crest, K 20

Results

The exit loss is the velocity head, the 1 in (1 + K_t): do not include it in K_t as well.

Velocity in the pipe2.8993m/s
Flow20.494m³/h
Absolute pressure at the crest0.69168bar
Highest crest before the pressure reaches vapour pressure8.8283m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 m level difference, 2 m crest, 50 mm, K 6. The inputs, in the units selected above:

InputValue
Level difference between the two surfaces3.0000 m
Height of the crest above the upper surface2.0000 m
Pipe inside diameter50.000 mm
Loss coefficient: entry, bends and friction f L/d, without the exit6.0000 -
Loss coefficient from the inlet to the crest2.0000 -
Liquid density998.00 kg/m³
Vapour pressure of the liquid0.023390 bar
Atmospheric pressure1.0132 bar

Applying the formula below gives:

ResultValue
Velocity in the pipe2.8993 m/s
Flow20.494 m³/h
Absolute pressure at the crest0.69168 bar
Highest crest before the pressure reaches vapour pressure8.8283 m

Open this example in the calculator and change any input.

Formula

\(v = \sqrt{\frac{2 g H}{1 + K_t}}, \quad p_c = p_a - \rho g z_c - (1 + K_c)\frac{\rho v^2}{2}\)

\(Q = v\frac{\pi d^2}{4}, \quad z_{max} = \frac{p_a - p_v - (1 + K_c)\rho v^2/2}{\rho g}\)

Variables

Symbol Meaning SI unit
\(H\) Level difference between the two surfaces m
\(z_c\) Height of the crest above the upper surface m
\(d\) Pipe inside diameter m
\(K_t\) Loss coefficient: entry, bends and friction f L/d, without the exit -
\(K_c\) Loss coefficient from the inlet to the crest -
\(\rho\) Liquid density kg/m³
\(p_v\) Vapour pressure of the liquid Pa
\(p_a\) Atmospheric pressure Pa
\(v\) Velocity in the pipe m/s
\(Q\) Flow m³/s
\(p_c\) Absolute pressure at the crest Pa
\(z_{max}\) Highest crest before the pressure reaches vapour pressure m
\(g\) Standard gravity, 9.806 65 m/s²

Method and standards

Bernoulli with losses.

Where it is used

  • Draining tanks and pits.
  • Cooling water and condensate siphons.

Common mistakes

  • Ignoring vapour pressure.
  • Counting the exit loss twice: it is the 1 in (1 + K_t), so K_t excludes it.

Assumptions and limits

  • Steady, full-bore flow.
  • K_t covers entry, bends and friction; the exit loss (one velocity head) is already in the formula as the 1.
  • When the crest pressure would fall below the vapour pressure the siphon breaks: flow, velocity and crest pressure are not shown.

References

  • Bernoulli with losses between the surfaces and to the crest (Textbook fluid mechanics (White, Fluid Mechanics))

Questions and answers

3 m level difference, 50 mm pipe, total K = 6?

Velocity 2.90 m/s, 20.5 m³/h.

How high can the crest be?

Below about 10 m for cold water, less with flow losses and warm water.

Why does warm water break a siphon?

Its vapour pressure is higher, so it boils at the crest sooner.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.