FireCADCalc

Bingham Plastic Pipe Flow: Hedström Number and Pressure Drop

Pressure drop of a Bingham plastic in a pipe: Buckingham–Reiner laminar solution, Hedström number and Darby's turbulent and combined friction factor.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Sludge 10 Pa, 50 mPa s, DN100Drilling mud 5 Pa, 20 mPa s, 3 m/s

Results

The combined factor follows the laminar value at low Re_B and the turbulent value at high Re_B. Rheology from a viscometer at the pipe's shear rates governs the accuracy.

Bingham Reynolds number3,989.7
Hedström number54,420
Laminar Fanning friction factor0.012778
Turbulent Fanning friction factor (Darby)0.006176
Combined friction factor0.012778
Pressure drop73.071kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sludge 10 Pa, 50 mPa s, DN100. The inputs, in the units selected above:

InputValue
Yield stress10.000 Pa
Plastic viscosity50.000 cP
Density1,300.0 kg/m³
Pipe inside diameter102.30 mm
Mean velocity1.5000 m/s
Pipe length100.00 m

Applying the formula below gives:

ResultValue
Bingham Reynolds number3,989.7
Hedström number54,420
Laminar Fanning friction factor0.012778
Turbulent Fanning friction factor (Darby)0.006176
Combined friction factor0.012778
Pressure drop73.071 kPa

Open this example in the calculator and change any input.

Formula

\(\frac{8V}{D} = \frac{\tau_w}{\mu_p}\left(1 - \frac43\xi + \frac13\xi^4\right), \ \xi = \frac{\tau_y}{\tau_w}, \quad f_L = \frac{2\tau_w}{\rho V^2}, \quad He = \frac{\rho D^2\tau_y}{\mu_p^2}\)

\(f_T = \frac{10^{a}}{Re_B^{0.193}}, \ a = -1.47\left[1 + 0.146e^{-2.9\times10^{-5}He}\right], \quad f = \left(f_L^m + f_T^m\right)^{1/m}, \ m = 1.7 + \frac{40000}{Re_B}\)

Variables

Symbol Meaning SI unit
\(\tau_y\) Yield stress Pa
\(\mu_p\) Plastic viscosity Pa·s
\(\rho\) Density kg/m³
\(D\) Pipe inside diameter m
\(V\) Mean velocity m/s
\(L\) Pipe length m
\(Re_B\) Bingham Reynolds number -
\(He\) Hedström number -
\(f_L\) Laminar Fanning friction factor -
\(f_T\) Turbulent Fanning friction factor (Darby) -
\(f\) Combined friction factor -
\(\Delta p\) Pressure drop Pa

Method and standards

Buckingham–Reiner laminar solution and Darby's combined correlation.

Where it is used

  • Sludge, mud and paste lines.
  • Ash slurry and lime slurry systems.

Common mistakes

  • Using a power-law fit for a fluid with a clear yield stress.
  • Ignoring the start-up pressure to break the yield stress.

Assumptions and limits

  • Bingham model; smooth pipes only (Darby's turbulent correlation has no roughness term).
  • The laminar–turbulent transition Reynolds number, which rises with He, is not reported; the combined factor bridges the two regimes.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 6
  • Eqs. (6-66) and (6-67) and Table 6-9 (Bingham plastics, Hedström number)
  • Buckingham–Reiner laminar solution; Darby
  • Mun and Boger (1992)
  • Chem. Eng. 99(9): 116 (turbulent and combined friction factor)

Questions and answers

What is a Bingham plastic?

A material that does not flow until the shear stress exceeds a yield stress, then flows with a constant plastic viscosity: toothpaste, drilling mud, sewage sludge, concentrated slurries.

What does the Hedström number tell me?

How strong the yield stress is relative to viscous forces; it raises the critical Reynolds number for turbulence.

Why is the laminar friction factor so high?

Part of the pipe cross-section moves as an unsheared plug, so more pressure is needed to shear the rest.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.