Worked example
Example: 0.3 m deep at 6 m/s, 2 m wide. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Depth before the jump | 0.30000 m |
| Velocity before the jump | 6.0000 m/s |
| Water density (for the power lost) | 998.00 kg/m³ |
| Channel width (for the power lost) | 2.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Froude number before the jump | 3.4981 |
| Depth after the jump | 1.3417 m |
| Head lost (y₂ − y₁)³/(4 y₁ y₂) | 0.70205 m |
| Power dissipated | 24.735 kW |
Open this example in the calculator and change any input.
Formula
\(Fr_1 = \frac{v_1}{\sqrt{g y_1}}, \quad \frac{y_2}{y_1} = \frac{1}{2}\left(\sqrt{1 + 8 Fr_1^2} - 1\right), \quad \Delta E = \frac{(y_2 - y_1)^3}{4 y_1 y_2}, \quad P_L = \rho g\,v_1 y_1 b\,\Delta E\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_1\) | Depth before the jump | m |
| \(v_1\) | Velocity before the jump | m/s |
| \(\rho\) | Water density (for the power lost) | kg/m³ |
| \(b\) | Channel width (for the power lost) | m |
| \(Fr_1\) | Froude number before the jump | - |
| \(y_2\) | Depth after the jump | m |
| \(\Delta E\) | Head lost (y₂ − y₁)³/(4 y₁ y₂) | m |
| \(P_L\) | Power dissipated | W |
Method and standards
Momentum across the jump.
Where it is used
- Spillways and outfalls.
- Hydraulics examinations.
Common mistakes
- Using it for sloping channels.
- Fr from the wrong depth.
Assumptions and limits
- Horizontal, rectangular.
References
- Momentum balance across a jump (Bélanger); Chow
- Open-Channel Hydraulics
Questions and answers
0.3 m deep at 6 m/s: what jump?
Fr₁ 3.50; depth after 1.34 m.
Why build stilling basins?
The jump dissipates energy safely before the water reaches the channel.
What if Fr is below 1?
The flow is already subcritical: there is no jump.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.