Worked example
Example: Sand 0.6 mm, 2600 kg/m³, bed 850 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean particle diameter | 0.60000 mm |
| Particle density | 2,600.0 kg/m³ |
| Gas (bed) temperature | 850.00 °C |
| Gas pressure (absolute) | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum fluidisation velocity | 0.12320 m/s |
| Archimedes number | 864.21 |
| Reynolds number at minimum fluidisation | 0.51915 |
| Gas density (air) | 0.31429 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(Ar = \frac{d_p^3\,\rho_g(\rho_p - \rho_g)\,g}{\mu^2} \qquad Re_{mf} = \sqrt{33.7^2 + 0.0408\,Ar} - 33.7 \qquad U_{mf} = \frac{Re_{mf}\,\mu}{\rho_g\,d_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | mean particle diameter | m |
| \(\rho_p\) | particle density | kg/m³ |
| \(T\) | gas temperature | K |
| \(p\) | gas pressure | Pa |
| \(U_{mf}\) | minimum fluidisation velocity | m/s |
| \(Ar\) | Archimedes number | – |
| \(Re_{mf}\) | Reynolds number at U_mf | – |
| \(\rho_g\) | gas density | kg/m³ |
| \(\mu\) | gas viscosity | Pa·s |
| \(g\) | standard gravity, 9.80665 | m/s² |
Method and standards
Wen and Yu (1966) correlation; air density by the ideal-gas law and viscosity from FireCAD's Sutherland–Wilke model of dry air.
Where it is used
- AFBC and CFBC boiler design and operation.
- Choosing bed material size.
- Cold fluidisation tests.
Common mistakes
- Using sieve size for irregular particles without a shape factor.
- Using cold-air properties at bed temperature.
- Confusing minimum fluidisation with operating velocity.
Assumptions and limits
- Spherical-equivalent particles of one size; air as the fluidising gas (flue gas in a firing bed differs by a few per cent in density and viscosity).
- The fluidisation regime calculator uses Grace's constants (27.2 and 0.0408) instead of Wen and Yu's 33.7 and 0.0408, so it gives a somewhat different U_mf for the same particle; both are published fits.
References
- C.Y. Wen and Y.H. Yu (1966)
- Air viscosity by Sutherland's law for each gas mixed by Wilke's rule
- density by the ideal-gas law
Questions and answers
What is the minimum fluidisation velocity of bed sand?
For 0.6 mm sand of 2600 kg/m³ at 850 °C, Ar = 864 and U_mf = 0.12 m/s. Bubbling beds run at several times this.
Why is U_mf lower when hot?
Hot gas is thinner but much more viscous; for fine particles the viscosity wins, so U_mf falls as the bed heats up.
Can I check it cold?
Yes: run the same calculation at room temperature to set fluidising tests on a cold bed, then convert.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.