FireCADCalc

Coal Devolatilisation: Time for a Fraction of Volatiles

Time to release a fraction of a coal particle's volatiles (La Nauze shrinking core) and the devolatilisation–combustion time t_v = a dᵖ (Basu Eqs. 4.3–4.4).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 90 % in a 30 s cook, 6 mm coalHalf released, fine coal

Results

Both τ_C and a must come from tests on the coal at the bed temperature and particle size of interest; the two times are separate correlations and are not linked to each other.

Time to release the fraction x16.610s
Devolatilisation and volatile combustion time30.000s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 90 % in a 30 s cook, 6 mm coal. The inputs, in the units selected above:

InputValue
Fraction of volatiles released90.000 %
Time for complete devolatilisation30.000 s
Pillai constant a (s per mm^p)5.0000 -
Exponent p1.0000 -
Coal particle diameter6.0000 mm

Applying the formula below gives:

ResultValue
Time to release the fraction x16.610 s
Devolatilisation and volatile combustion time30.000 s

Open this example in the calculator and change any input.

Formula

\(\frac{t}{\tau_C} = 1 - 3(1 - x)^{2/3} + 2(1 - x), \quad t_v = a\,d_v^{\,p}\ (d_v\ \text{in mm})\)

Variables

Symbol Meaning SI unit
\(x\) Fraction of volatiles released -
\(\tau_C\) Time for complete devolatilisation s
\(a\) Pillai constant a (s per mm^p) -
\(p\) Exponent p -
\(d_v\) Coal particle diameter m
\(t\) Time to release the fraction x s
\(t_v\) Devolatilisation and volatile combustion time s

Method and standards

Shrinking-core relation and Pillai's empirical fit.

Where it is used

  • Fuel size and feed point design.

Common mistakes

  • Using constants from another coal or temperature.

Assumptions and limits

  • Constants from tests. The calculator does not scale them: \(\tau_C\) grows roughly with the square of particle size and \(a\) falls steeply with temperature (about \(T^{-3.8}\)), so enter values measured at your size and bed temperature.
  • The two outputs come from separate correlations: \(t\) from the \(\tau_C\) you enter and \(t_v\) from \(a\), \(p\) and \(d_v\). They are not linked and can disagree.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 4
  • Eqs. (4.3) (La Nauze 1985) and (4.4) (Pillai 1981)

Questions and answers

Why does devolatilisation matter?

Volatiles released low in the bed burn there; large coal releases them higher, shifting heat release up the furnace.

What exponent p is typical?

Basu quotes 0.32 to 1.8.

Where do τ_C and a come from?

Tests on the coal at bed temperature; a falls steeply with temperature (∝ T⁻³·⁸).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.