Choking Velocity and Voidage (Yang) for a Fast Bed

Choking velocity and voidage marking the transition to fast fluidisation for a solids circulation rate, by solving Yang's correlation (Basu Eqs. 2.12–2.13).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: Basu's example: 30 kg/m2 s at 825 °CLarger riser 1 m, 50 kg/m2 s

Results

Voidage at choking99.760%
Slip at choking5.0015m/s
Choking velocity7.7050m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Basu's example: 30 kg/m2 s at 825 °C. The inputs, in the units selected above:

InputValue
Solids circulation rate30.000 kg/(m²·s)
Particle terminal velocity2.7220 m/s
Particle density2,500.0 kg/m³
Gas density0.31600 kg/m³
Equivalent column diameter0.20300 m

Applying the formula below gives:

ResultValue
Voidage at choking99.760 %
Slip at choking5.0015 m/s
Choking velocity7.7050 m/s

Open this example in the calculator and change any input.

Formula

\(\frac{U_{ch}}{\varepsilon_c} - U_t = \left[\frac{2gD(\varepsilon_c^{-4.7} - 1)}{6.81\times10^5}\left(\frac{\rho_p}{\rho_g}\right)^{2.2}\right]^{0.5}, \quad G_s = \left(\frac{U_{ch}}{\varepsilon_c} - U_t\right)(1 - \varepsilon_c)\rho_p\)

Variables

Symbol Meaning SI unit
\(G_s\) Solids circulation rate kg/(m²·s)
\(U_t\) Particle terminal velocity m/s
\(\rho_p\) Particle density kg/m³
\(\rho_g\) Gas density kg/m³
\(D\) Equivalent column diameter m
\(\varepsilon_c\) Voidage at choking -
\(U_{ch}/\varepsilon_c - U_t\) Slip at choking m/s
\(U_{ch}\) Choking velocity m/s

Method and standards

Yang's correlation solved by bisection on ε_c between 0.5 and 1; a choking voidage below 0.5 is reported as no solution. Standard gravity 9.80665 m/s².

Where it is used

  • CFB riser design checks.

Common mistakes

  • Extrapolating far beyond small-column data.
  • Using bed-average terminal velocity for a wide size range.

Assumptions and limits

  • Group A data base from columns under 0.3 m; first approximation for boilers (a warning appears above 0.3 m, where \(U_{ch}\) is extrapolated with \(\sqrt{D}\)).

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2
  • Eqs. (2.12) and (2.13) (Yang 1983) and the worked example of section 2.2

Questions and answers

What is choking?

The velocity below which a column can no longer carry the solids fed to it in dilute flow; the bed collapses into a dense suspension.

Why does circulation rate matter?

More solids need a higher gas velocity to stay in dilute transport.

What does Basu's example give?

A 0.203 m column at 825 °C with 30 kg/m²·s: U_ch ≈ 7.7 m/s, ε_c ≈ 0.9976.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.