CFB Furnace Membrane Wall Area and Heat Absorbed

Projected and actual membrane wall area of a CFB furnace, wall temperature by Basu's rule and the heat the walls absorb (Basu Eqs. 6.14–6.17).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 15 × 8 m, 30 m water-cooled, 63.5/88.9 mmSmall CFB 6 × 4 × 20 m

Results

Basu also takes superheater and reheater metal at steam temperature + 50 °C (Eq. 10.2); refractory-lined lower walls absorb little and are left out of L.

Actual-to-projected area ratio1.4077
Projected wall area1,380.0m²
Actual heat-transfer area1,942.6m²
Wall temperature (T_sat + 25 °C)345.00°C
Heat absorbed by the walls125.44MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 × 8 m, 30 m water-cooled, 63.5/88.9 mm. The inputs, in the units selected above:

InputValue
Furnace width15.000 m
Furnace breadth (depth)8.0000 m
Water-cooled height30.000 m
Tube outer diameter63.500 mm
Tube pitch88.900 mm
Heat transfer coefficient on the projected area180.00 W/(m²·K)
Bed temperature850.00 °C
Saturation temperature at drum pressure320.00 °C

Applying the formula below gives:

ResultValue
Actual-to-projected area ratio1.4077
Projected wall area1,380.0 m²
Actual heat-transfer area1,942.6 m²
Wall temperature (T_sat + 25 °C)345.00 °C
Heat absorbed by the walls125.44 MW

Open this example in the calculator and change any input.

Formula

\(A_x = \frac{\pi D/2 + p - D}{p}, \quad A_w = 2(W + B)L, \quad A_{actual} = A_xA_w, \quad Q_w = A_wU_h(T_b - T_{wall}), \quad T_{wall} = T_{sat} + 25\ \text{K}\)

Variables

Symbol Meaning SI unit
\(W\) Furnace width m
\(B\) Furnace breadth (depth) m
\(L\) Water-cooled height m
\(D\) Tube outer diameter m
\(p\) Tube pitch m
\(U_h\) Heat transfer coefficient on the projected area W/(m²·K)
\(T_b\) Bed temperature K
\(T_{sat}\) Saturation temperature at drum pressure K
\(A_x\) Actual-to-projected area ratio -
\(A_w\) Projected wall area m²
\(A_{actual}\) Actual heat-transfer area m²
\(T_{wall}\) Wall temperature (T_sat + 25 °C) K
\(Q_w\) Heat absorbed by the walls W

Method and standards

Basu's design equations.

Where it is used

  • CFB furnace surface sizing.

Common mistakes

  • Including refractory-lined walls in L.
  • Mixing projected-area and actual-area coefficients.

Assumptions and limits

  • Roof and exit areas taken as equal (Basu).
  • One average coefficient and bed temperature over the whole water-cooled height. In a CFB the coefficient falls strongly with suspension density up the furnace; use a height-averaged \(U_h\) or split the furnace into zones.
  • \(T_{sat}\) is entered directly; take it at the drum pressure from the saturation calculator.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 6
  • Eqs. (6.14)–(6.17) and ch. 10
  • Eq. (10.1) (evaporator wall at T_sat + 25 °C)

Questions and answers

What is A_x?

Actual tube-and-fin surface facing the furnace per unit projected area: half the tube circumference plus the fin, per pitch.

Which area goes with which coefficient?

Use the projected area with a coefficient based on it (U_h), or the actual area with a true local coefficient (U_c).

Why T_sat + 25 °C?

Boiling inside keeps the tube close to saturation; 25 K covers the tube wall and scale.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.