Worked example
Example: Basu's example sand 300 µm at 825 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean particle diameter (surface-volume) | 0.30000 mm |
| Particle density | 2,500.0 kg/m³ |
| Gas density | 0.31600 kg/m³ |
| Gas viscosity | 0.045000 cP |
| Bed (furnace) diameter or equivalent | 0.20300 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Archimedes number | 103.28 |
| Minimum fluidisation velocity | 0.036718 m/s |
| Onset of turbulent fluidisation | 3.9655 m/s |
| Turbulent regime fully developed | 6.1856 m/s |
| Transport velocity (Perales) | 6.4948 m/s |
| Minimum slugging velocity | 0.13548 m/s |
Open this example in the calculator and change any input.
Formula
\(Ar = \frac{\rho_g(\rho_p - \rho_g)gd_p^3}{\mu^2}, \quad Re_{mf} = \sqrt{27.2^2 + 0.0408Ar} - 27.2\)
\(Re_c = 0.936Ar^{0.472}, \quad Re_k = 1.46Ar^{0.472}, \quad U_{tr} = 1.45\frac{\mu}{\rho_gd_p}Ar^{0.484}, \quad U_{sl} = U_{mf} + 0.07\sqrt{gD}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | Mean particle diameter (surface-volume) | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_g\) | Gas density | kg/m³ |
| \(\mu\) | Gas viscosity | Pa·s |
| \(D\) | Bed (furnace) diameter or equivalent | m |
| \(Ar\) | Archimedes number | - |
| \(U_{mf}\) | Minimum fluidisation velocity | m/s |
| \(u_c\) | Onset of turbulent fluidisation | m/s |
| \(u_k\) | Turbulent regime fully developed | m/s |
| \(U_{tr}\) | Transport velocity (Perales) | m/s |
| \(U_{sl}\) | Minimum slugging velocity | m/s |
Method and standards
Correlations quoted by Basu, ch. 2.
Where it is used
- CFB and BFB furnace design.
- Bed material selection.
Common mistakes
- Using mean size by mass instead of surface-volume mean.
- Applying small-column correlations without margin.
Assumptions and limits
- Spherical-ish particles; correlations from small beds. The turbulent-transition values are indicative for large beds, and slugging does not occur in beds wider than about a metre (notes appear).
- Standard gravity 9.80665 m/s².
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 2
- Eqs. (2.3) (Grace: C₁ 27.2, C₂ 0.0408)
- (2.7) (Stewart and Davidson)
- (2.10)–(2.11) (Horio and Morishita)
- (2.14) (Perales et al.)
Questions and answers
Which regime do CFB boilers run in?
Fast fluidisation, above the transport velocity, typically 4–6 m/s.
Which do bubbling beds use?
1–3 m/s, above U_mf but below the turbulent transition.
Why does slugging not matter for boilers?
Basu notes commercial beds are too wide for bubbles to grow to the bed diameter.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.