Worked example
Example: Bubbling bed 1.5 m/s, 0.8 m bed, 4 mm orifices. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Superficial velocity through the grid | 1.5000 m/s |
| Expanded bed height (at the operating voidage) | 0.80000 m |
| Particle density | 2,600.0 kg/m³ |
| Distributor-to-bed pressure drop ratio | 30.000 % |
| Gas density in the bed | 0.32000 kg/m³ |
| Gas density at the orifice | 0.90000 kg/m³ |
| Orifice coefficient | 0.80000 - |
| Orifice diameter | 4.0000 mm |
| Orifices per nozzle | 6.0000 - |
| Grid area | 20.000 m² |
| Bed particle size | 0.50000 mm |
| Orifice pitch layout | Triangular |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bed voidage (King) | 71.429 % |
| Bed pressure drop | 5.8280 kPa |
| Distributor pressure drop | 1.7484 kPa |
| Orifice velocity | 49.866 m/s |
| Fractional opening | 1.0695 % |
| Orifices per m² | 851.11 |
| Orifice pitch | 36.833 mm |
| Nozzles on the grid | 2,838.0 |
| Jet length above the orifice (Merry) | 124.80 mm |
Open this example in the calculator and change any input.
Formula
\(\Delta P_{dist} = k\Delta P_b, \quad \Delta P_b = \rho_p(1 - \varepsilon)Hg, \quad \varepsilon = \frac{U + 1}{U + 2}, \quad U_0 = C_D\sqrt{\frac{2\Delta P_{dist}}{\rho_{g,or}}}\)
\(\phi = \frac{U\rho_g}{U_0\rho_{g,or}} = N\frac{\pi d_0^2}{4}, \quad \frac{l_j}{d_0} = 5.2\left(\frac{\rho_{g,or}d_0U_0}{\rho_pd_p}\right)^{0.3}\left[1.3\left(\frac{U_0^2}{gd_0}\right)^{0.2} - 1\right]\)
\(P = \sqrt{\frac{2}{\sqrt3\,N}}\ \text{(triangular)}, \quad P = \sqrt{\frac{1}{N}}\ \text{(square)}, \quad N_n = \left\lceil \frac{N\,A}{n} \right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(U\) | Superficial velocity through the grid | m/s |
| \(H\) | Expanded bed height at the operating voidage | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(k\) | Distributor-to-bed pressure drop ratio | - |
| \(\rho_g\) | Gas density in the bed | kg/m³ |
| \(\rho_{g,or}\) | Gas density at the orifice | kg/m³ |
| \(C_D\) | Orifice coefficient | - |
| \(d_0\) | Orifice diameter | m |
| \(n\) | Orifices per nozzle | - |
| \(A\) | Grid area | m² |
| \(d_p\) | Bed particle size | m |
| \(\text{pitch}\) | Orifice pitch layout | - |
| \(\varepsilon\) | Bed voidage (King) | - |
| \(\Delta P_b\) | Bed pressure drop | Pa |
| \(\Delta P_{dist}\) | Distributor pressure drop | Pa |
| \(U_0\) | Orifice velocity | m/s |
| \(\phi\) | Fractional opening | - |
| \(N\) | Orifices per m² | - |
| \(P\) | Orifice pitch | m |
| \(N_n\) | Nozzles on the grid | - |
| \(l_j\) | Jet length above the orifice (Merry) | m |
Method and standards
Basu's distributor design procedure: bed pressure drop from King's voidage, the distributor drop as a share of it (Kunii–Levenspiel), orifice velocity with \(C_D\) = 0.8 (Zenz), the fractional opening and orifice count, and Merry's jet length.
Where it is used
- Bubbling bed, loop seal and FBHE grids.
Common mistakes
- Designing for full load only (grid ΔP falls with U² at low load).
- Ignoring orifice gas density.
Assumptions and limits
- King's voidage for velocities up to 5 m/s; above that a warning is given.
- The bed height is the expanded height at that voidage; entering the settled height understates the bed pressure drop.
- The pitch spreads the orifices uniformly over the grid; with nozzle caps of \(n\) orifices each, the nozzle pitch is wider. A negative jet length from Merry's correlation is shown as zero.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 8
- Eqs. (8.15)–(8.23): Kunii–Levenspiel pressure-drop rule
- King's voidage
- Zenz C_D = 0.8
- Merry's jet length
Questions and answers
Why must the grid drop be large?
It must exceed bed pressure non-uniformity, or air channels through weak spots.
What fractional opening is usual?
About 1–2 % for bubbling beds.
Why keep tubes above the jet length?
Solids carried by the orifice jets erode tubes they hit.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.