Fluidised-Bed Air Distributor: Orifices, Pitch and Nozzles

Distributor pressure drop, orifice velocity, fractional opening, orifices per m², pitch, nozzles and jet length for a bubbling bed grid (Basu Eqs. 8.15–8.22).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: Bubbling bed 1.5 m/s, 0.8 m bed, 4 mm orificesLoop seal grid, square pitch

Results

Orifice velocity above 30 m/s: check particle attrition (Pell suggests below 30 m/s).

Bed voidage (King)71.429%
Bed pressure drop5.8280kPa
Distributor pressure drop1.7484kPa
Orifice velocity49.866m/s
Fractional opening1.0695%
Orifices per m²851.11
Orifice pitch36.833mm
Nozzles on the grid2,838.0
Jet length above the orifice (Merry)124.80mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bubbling bed 1.5 m/s, 0.8 m bed, 4 mm orifices. The inputs, in the units selected above:

InputValue
Superficial velocity through the grid1.5000 m/s
Expanded bed height (at the operating voidage)0.80000 m
Particle density2,600.0 kg/m³
Distributor-to-bed pressure drop ratio30.000 %
Gas density in the bed0.32000 kg/m³
Gas density at the orifice0.90000 kg/m³
Orifice coefficient0.80000 -
Orifice diameter4.0000 mm
Orifices per nozzle6.0000 -
Grid area20.000 m²
Bed particle size0.50000 mm
Orifice pitch layoutTriangular

Applying the formula below gives:

ResultValue
Bed voidage (King)71.429 %
Bed pressure drop5.8280 kPa
Distributor pressure drop1.7484 kPa
Orifice velocity49.866 m/s
Fractional opening1.0695 %
Orifices per m²851.11
Orifice pitch36.833 mm
Nozzles on the grid2,838.0
Jet length above the orifice (Merry)124.80 mm

Open this example in the calculator and change any input.

Formula

\(\Delta P_{dist} = k\Delta P_b, \quad \Delta P_b = \rho_p(1 - \varepsilon)Hg, \quad \varepsilon = \frac{U + 1}{U + 2}, \quad U_0 = C_D\sqrt{\frac{2\Delta P_{dist}}{\rho_{g,or}}}\)

\(\phi = \frac{U\rho_g}{U_0\rho_{g,or}} = N\frac{\pi d_0^2}{4}, \quad \frac{l_j}{d_0} = 5.2\left(\frac{\rho_{g,or}d_0U_0}{\rho_pd_p}\right)^{0.3}\left[1.3\left(\frac{U_0^2}{gd_0}\right)^{0.2} - 1\right]\)

\(P = \sqrt{\frac{2}{\sqrt3\,N}}\ \text{(triangular)}, \quad P = \sqrt{\frac{1}{N}}\ \text{(square)}, \quad N_n = \left\lceil \frac{N\,A}{n} \right\rceil\)

Variables

Symbol Meaning SI unit
\(U\) Superficial velocity through the grid m/s
\(H\) Expanded bed height at the operating voidage m
\(\rho_p\) Particle density kg/m³
\(k\) Distributor-to-bed pressure drop ratio -
\(\rho_g\) Gas density in the bed kg/m³
\(\rho_{g,or}\) Gas density at the orifice kg/m³
\(C_D\) Orifice coefficient -
\(d_0\) Orifice diameter m
\(n\) Orifices per nozzle -
\(A\) Grid area m²
\(d_p\) Bed particle size m
\(\text{pitch}\) Orifice pitch layout -
\(\varepsilon\) Bed voidage (King) -
\(\Delta P_b\) Bed pressure drop Pa
\(\Delta P_{dist}\) Distributor pressure drop Pa
\(U_0\) Orifice velocity m/s
\(\phi\) Fractional opening -
\(N\) Orifices per m² -
\(P\) Orifice pitch m
\(N_n\) Nozzles on the grid -
\(l_j\) Jet length above the orifice (Merry) m

Method and standards

Basu's distributor design procedure: bed pressure drop from King's voidage, the distributor drop as a share of it (Kunii–Levenspiel), orifice velocity with \(C_D\) = 0.8 (Zenz), the fractional opening and orifice count, and Merry's jet length.

Where it is used

  • Bubbling bed, loop seal and FBHE grids.

Common mistakes

  • Designing for full load only (grid ΔP falls with U² at low load).
  • Ignoring orifice gas density.

Assumptions and limits

  • King's voidage for velocities up to 5 m/s; above that a warning is given.
  • The bed height is the expanded height at that voidage; entering the settled height understates the bed pressure drop.
  • The pitch spreads the orifices uniformly over the grid; with nozzle caps of \(n\) orifices each, the nozzle pitch is wider. A negative jet length from Merry's correlation is shown as zero.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 8
  • Eqs. (8.15)–(8.23): Kunii–Levenspiel pressure-drop rule
  • King's voidage
  • Zenz C_D = 0.8
  • Merry's jet length

Questions and answers

Why must the grid drop be large?

It must exceed bed pressure non-uniformity, or air channels through weak spots.

What fractional opening is usual?

About 1–2 % for bubbling beds.

Why keep tubes above the jet length?

Solids carried by the orifice jets erode tubes they hit.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.