Worked example
Example: 800 m2 superheater FBHE. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Overall heat transfer coefficient of the tubes | 300.00 W/(m²·K) |
| Tube outside area | 800.00 m² |
| Solids in | 870.00 °C |
| Solids out | 700.00 °C |
| Steam or water in | 400.00 °C |
| Steam or water out | 540.00 °C |
| Solids specific heat | 0.90000 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean temperature difference, well-mixed bed at the solids outlet temperature | 222.71 K |
| Duty | 53.451 MW |
| Solids flow for the temperature drop | 1,257.7 t/h |
Open this example in the calculator and change any input.
Formula
\(\Delta T_m = \frac{(T_{s,out} - T_{w,in}) - (T_{s,out} - T_{w,out})}{\ln\frac{T_{s,out} - T_{w,in}}{T_{s,out} - T_{w,out}}}, \quad Q = H_{tube}A_0\,\Delta T_m, \quad \dot m_s = \frac{Q}{c_s(T_{s,in} - T_{s,out})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H_{tube}\) | Overall heat transfer coefficient of the tubes | W/(m²·K) |
| \(A_0\) | Tube outside area | m² |
| \(T_{s,in}\) | Solids in | K |
| \(T_{s,out}\) | Solids out, which is also the temperature of the well-mixed bed | K |
| \(T_{w,in}\) | Steam or water in | K |
| \(T_{w,out}\) | Steam or water out | K |
| \(c_s\) | Solids specific heat | J/(kg·K) |
| \(\Delta T_m\) | Mean temperature difference between the bed and the steam or water | K |
| \(Q_{FBHE}\) | Duty | W |
| \(\dot m_s\) | Solids flow for the temperature drop | kg/s |
Method and standards
Basu's Eq. (3.24), Q = H_tube A₀ ΔT, with a solids heat balance. The FBHE is a bubbling bed, which is well mixed: the whole bed, and the solids leaving it, are at one temperature, T_s,out. The steam or water in the tubes heats from T_w,in to T_w,out against that constant bed temperature, so the mean difference is the log mean of (T_s,out − T_w,in) and (T_s,out − T_w,out).
Where it is used
- CFB loop design.
Common mistakes
- Using furnace wall coefficients for immersed tubes.
- Using the counter-flow LMTD with the solids inlet temperature: a well-mixed bed never sees the solids inlet temperature at the tubes, and that LMTD overstates the duty.
Assumptions and limits
- Well-mixed bed at the solids outlet temperature. A bed divided into compartments in series comes closer to counter-flow and absorbs somewhat more.
- An evaporator (water in and out at the same saturation temperature) is accepted.
- The bed must be hotter than the steam or water leaving the tubes.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 3
- Eq. (3.24): Q = H_tube A₀ LMTD
Questions and answers
Why an external heat exchanger?
To absorb heat outside the furnace where bed temperature and heat absorption can be controlled independently.
Is the solids side counter-current?
No: a bubbling FBHE is well mixed, so the tubes see one bed temperature, the solids outlet temperature, and the calculation uses that.
What coefficients apply?
300–600 W/m²·K for immersed tubes in a bubbling FBHE.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.