FireCADCalc

CFB Loop Seal: Standpipe Diameter and Seal Dimensions

Standpipe diameter for the solids flow per cyclone at a chosen solids velocity, loop seal length and breadth, and the opening height (Basu Eqs. 8.12–8.14).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 15 kg/m2 s, 60 m2, 3 cyclonesSmall CFB, 1 cyclone

Rounded to a whole number.
Basu suggests about 0.15 m/s and never above 1 m/s.

Results

Solids flow per loop seal1,080.0t/h
Standpipe diameter1,427.3mm
Loop seal length (2.5 d_s)3,568.2mm
Loop seal breadth (1.25 d_s)1,784.1mm
Height of the opening1,345.2mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 kg/m2 s, 60 m2, 3 cyclones. The inputs, in the units selected above:

InputValue
Solids circulation flux in the furnace15.000 kg/(m²·s)
Furnace cross-section60.000 m²
Number of cyclones (loop seals)3.0000 -
Voidage of solids in the standpipe50.000 %
Particle density2,500.0 kg/m³
Solids velocity in the standpipe0.15000 m/s
Horizontal solids velocity through the opening0.10000 m/s

Applying the formula below gives:

ResultValue
Solids flow per loop seal1,080.0 t/h
Standpipe diameter1,427.3 mm
Loop seal length (2.5 d_s)3,568.2 mm
Loop seal breadth (1.25 d_s)1,784.1 mm
Height of the opening1,345.2 mm

Open this example in the calculator and change any input.

Formula

\(W_s = \frac{G_sA_f}{n_c}, \quad d_s = \sqrt{\frac{4W_s}{\pi(1 - \varepsilon_s)\rho_pV_s}}, \quad L = 2.5\,d_s, \quad B = 1.25\,d_s, \quad h_o = \frac{W_s}{(1 - \varepsilon_s)\rho_pV_hB}\)

Variables

Symbol Meaning SI unit
\(G_s\) Solids circulation flux in the furnace kg/(m²·s)
\(A_f\) Furnace cross-section m²
\(n_c\) Number of cyclones (loop seals) -
\(\varepsilon_s\) Voidage of solids in the standpipe -
\(\rho_p\) Particle density kg/m³
\(V_s\) Solids velocity in the standpipe m/s
\(V_h\) Horizontal solids velocity through the opening m/s
\(W_s\) Solids flow per loop seal kg/s
\(d_s\) Standpipe diameter m
\(L\) Loop seal length (2.5 d_s) m
\(B\) Loop seal breadth (1.25 d_s) m
\(h_o\) Height of the opening m

Method and standards

Basu's loop seal sizing: the solids flow per loop seal sets the standpipe diameter at the chosen solids velocity (Eqs. 8.12–8.13), the seal length and breadth follow Basu's proportions, and the opening height gives the chosen horizontal solids velocity (Eq. 8.14). The number of cyclones is rounded to a whole number.

Where it is used

  • CFB loop design.

Common mistakes

  • Using total circulation instead of per loop seal.
  • Too high a standpipe velocity.

Assumptions and limits

  • Guideline proportions, not mandatory.
  • Warnings appear for a standpipe solids velocity above 1 m/s and a horizontal velocity outside 0.05–0.25 m/s. The opening height is not checked against the seal dimensions: check it fits below the weir.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 8
  • Eqs. (8.12)–(8.14) and guidelines L = 2.5 d_s
  • B = 1.25 d_s

Questions and answers

What solids velocity should I use?

Basu suggests about 0.15 m/s and never above 1 m/s.

Why an opening between chambers?

Solids pass under a weir from the supply to the recycle chamber; its height sets a horizontal solids velocity of 0.05–0.25 m/s.

Is this the only method?

Basu also allows taking the cyclone's bottom outlet as the standpipe if the solids velocity stays below 1 m/s.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.