Worked example
Example: Nitrifying filter, Nox/BOD 0.25, 25 C air. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wastewater flow | 8,000.0 m³/d |
| Primary effluent BOD | 120.00 mg/L |
| BOD loading (kg/m³·d) | 0.40000 - |
| Organic peaking factor | 1.3000 - |
| Nitrogen oxidised per BOD (0 for BOD removal only) | 0.25000 - |
| Warmest air temperature | 25.000 °C |
| Wastewater temperature | 18.000 °C |
| Site atmospheric pressure | 0.93758 atm |
| Tower diameter | 15.000 m |
| Number of towers | 2.0000 - |
| Packing depth | 6.0000 m |
| Packing correction (1.3 cross-flow, 2.0 rock) | 1.3000 - |
| Inlet and minor loss factor | 1.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oxygen supply (kg O₂ per kg BOD applied) | 119.23 |
| Air at 20 °C and 1 atm | 284.57 m³/min |
| Design air flow | 347.86 m³/min |
| Liquid loading per tower | 943.14 kg/(m²·h) |
| Velocity heads | 122.42 |
| Pressure drop through the tower | 0.018284 Pa |
| Natural draft | 0.84409 Pa |
Open this example in the calculator and change any input.
Formula
\(R_o = 20\left(0.80e^{-9L_B} + 1.2e^{-0.17L_B}\right)PF, \quad AR_{20} = \frac{R_oQS_o(3.58)}{10^3(1440)}, \quad AR = AR_{20}\frac{273.15 + T_a}{273.15}\frac{P_a}{P_b}\left(1 + \frac{T_a - 20}{100}\right)\)
\(N_p = f_mf_p\,10.33\,Ze^{1.36\times10^{-5}L/A}, \quad \Delta P = N_p\frac{\rho v^2}{2}, \quad D_{air} = 353\left(\frac1{T_c} - \frac1{T_m}\right)Z\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Wastewater flow | m³/s |
| \(S_o\) | Primary effluent BOD | kg/m³ |
| \(L_B\) | BOD loading (kg/m³·d) | - |
| \(PF\) | Organic peaking factor | - |
| \(N_{ox}/BOD\) | Nitrogen oxidised per BOD (0 for BOD removal only) | - |
| \(T_a\) | Warmest air temperature | K |
| \(T_w\) | Wastewater temperature | K |
| \(P_b\) | Site atmospheric pressure | Pa |
| \(D_t\) | Tower diameter | m |
| \(n\) | Number of towers | - |
| \(Z\) | Packing depth | m |
| \(f_p\) | Packing correction (1.3 cross-flow, 2.0 rock) | - |
| \(f_m\) | Inlet and minor loss factor | - |
| \(R_o\) | Oxygen supply (kg O₂ per kg BOD applied) | - |
| \(AR_{20}\) | Air at 20 °C and 1 atm | m³/s |
| \(AR\) | Design air flow | m³/s |
| \(L/A\) | Liquid loading per tower | kg/(m²·s) |
| \(N_p\) | Velocity heads | - |
| \(\Delta P\) | Pressure drop through the tower | Pa |
| \(D_{air}\) | Natural draft | Pa |
Method and standards
Trickling filter ventilation.
Where it is used
- Fan sizing for covered trickling filters.
- Odour-control air systems.
Common mistakes
- Using total flow on one tower's area.
- Ignoring the warm-weather air correction.
Assumptions and limits
- Empirical oxygen-supply relation; vertical packing correlation with factors.
Questions and answers
Why forced ventilation if draft exceeds the loss?
Draft depends on the air-water temperature difference and vanishes or reverses in mild weather; fans give a reliable oxygen supply and odour control.
What do the defaults represent?
An illustrative case: Nitrifying filter, Nox/BOD 0.25, 25 C air. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 9-2, eqs. 9-2 to 9-10 and Example 9-1