FireCADCalc

Cascade Post-aeration Height for a Dissolved Oxygen Target

Height of a step cascade that raises dissolved oxygen in treated effluent from its initial to its required value, by Barrett's deficit-ratio equation.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Free weir, 15 C, 2 to 7 mg/L

Accepted: 1 to 20 mg/L
Accepted: 0 to 20 mg/L
Accepted: 0 to 20 mg/L
Accepted: 0 to 40 °C
Accepted: 0.3 to 1.5
Accepted: 0.05 to 1 m

Results

Design for the warmest water: saturation falls with temperature, so the deficit ratio and the height rise. The typical cascades are 2-5 m high with 150-300 mm steps.

Deficit ratio2.6287
Cascade height3.3369m
Number of steps14.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Free weir, 15 C, 2 to 7 mg/L. The inputs, in the units selected above:

InputValue
Dissolved oxygen saturation at the water temperature10.070 mg/L
Dissolved oxygen entering2.0000 mg/L
Required final dissolved oxygen7.0000 mg/L
Water temperature15.000 °C
Water quality factor (0.8 treated effluent)0.80000 -
Weir geometry factorFree weir, 1.0
Step height0.25000 m

Applying the formula below gives:

ResultValue
Deficit ratio2.6287
Cascade height3.3369 m
Number of steps14.000

Open this example in the calculator and change any input.

Formula

\(R = \frac{C_s - C_o}{C_s - C}, \quad H = \frac{R - 1}{0.361\,ab(1 + 0.046T)}\)

Variables

Symbol Meaning SI unit
\(C_s\) Dissolved oxygen saturation at the water temperature kg/m³
\(C_o\) Dissolved oxygen entering kg/m³
\(C\) Required final dissolved oxygen kg/m³
\(T\) Water temperature K
\(a\) Water quality factor (0.8 treated effluent) -
\(b\) Weir geometry factor -
\(h_s\) Step height m
\(R\) Deficit ratio -
\(H\) Cascade height m
\(N\) Number of steps -

Method and standards

Barrett's cascade aeration equation (SI form).

Where it is used

  • Effluent post-aeration before discharge.
  • Using spare hydraulic head for reaeration.

Common mistakes

  • Designing for winter temperature.
  • Taking T in kelvin.

Assumptions and limits

  • Empirical; T in °C.

Questions and answers

Where do I get the saturation value?

From an oxygen solubility table or the dissolved gas saturation calculator: 9.09 mg/L at 20 °C and 8.26 mg/L at 25 °C in fresh water at sea level.

Why does the height grow so fast near saturation?

The deficit ratio (C_s − C_o)/(C_s − C) rises steeply as the target approaches saturation.

What do the defaults represent?

An illustrative case: Free weir, 15 C, 2 to 7 mg/L. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 5-11, eq. 5-83 and Example 5-16 (Barrett 1960)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.